Clin Endosc > Volume 55(3); 2022 > Article
CME for
KSGE members
Jeong, Kim, and Han: An unwonted complication of endoscopic retrograde cholangiopancreatography

Quiz

A 45-year-old man was admitted for the follow-up of benign biliary stricture after an episode of severe acute pancreatitis. He underwent endoscopic retrograde cholangiography (ERCP) three months prior. At that time, biliary sphincterotomy and stenting with a 10-Fr 7-cm stent (Cotton-Leung Biliary Stent; Cook Medical LLC, Bloomington, IN, USA) were performed, without complications. He had been abstinent from alcohol for the past eight months. He had no fever or abdominal pain. Abdominal examination showed a non-tender, flat abdomen. Complete blood count and liver function test results were all within normal ranges. Abdominal radiography revealed a biliary stent in the right upper quadrant (Fig. 1A). From abdominal computed tomography, the distal end of the biliary stent seemed to be slightly above the ampulla (Fig. 1B). ERCP was performed (Fig. 1C, D).
What is the most likely diagnosis?
 

NOTES

Conflicts of Interest
Jimin Han is currently serving as a CE Quiz Editor; however, Jimin Han was not involved in the peer reviewer selection, evaluation, or decision process of this manuscript. Han Taek Jeong and Ho Gak Kim have no potential conflicts of interest.
Funding
None.
Author Contributions
Conceptualization: HTJ, HGK, JH; Data curation: HTJ, HGK, JH; Investigation: HTJ, HGK, JH; Writing-original draft: JH; Writing-review & editing: HTJ, HGK, JH.

Fig. 1.
(A) Abdominal X-ray showed a biliary stent in the right upper quadrant. (B) Abdominal computed tomography revealed the biliary stent to be slightly above the ampulla (arrowhead). (C) Examination with the side-viewing duodenoscope showed evidence of prior sphincterotomy but no biliary stent at the bile duct orifice. (D) On fluoroscopy, the distal end of the biliary stent was located above the ampulla.
ce-2022-106f1.jpg
Fig. 2.
(A) A 0.035-inch guidewire was cannulated into the stent lumen. (B) A 7-Fr Soehendra stent retriever, which was placed over the guidewire, was screwed into the distal end of the stent. (C, D) Under endoscopic and fluoroscopic guidance, both the stent and the stent retriever were slowly pulled back into the duodenal lumen.
ce-2022-106f2.jpg

REFERENCES

1. Dumonceau J-M, Tringali A, Blero D, et al. Biliary stenting: indications, choice of stents and results: European Society of Gastrointestinal Endoscopy (ESGE) clinical guideline. Endoscopy 2012;44:277–298.
crossref pmid
2. Arhan M, Odemiş B, Parlak E, et al. Migration of biliary plastic stents: experience of a tertiary center. Surg Endosc 2009;23:769–775.
crossref pmid
3. Al Lehibi A, Al Mtawa A, Almasoudi T, et al. Removal of proximally migrated biliary stents by using single-operator cholangioscopy. VideoGIE 2020;5:213–216.
crossref pmid pmc
4. Calcara C, Broglia L, Comi G, et al. Plastic biliary stent migration during multiple stents placement and successful endoscopic removal using intra-stent balloon inflation technique: a case report and literature review. Am J Case Rep 2016;17:65–69.
crossref pmid pmc
5. Katsinelos P, Kountouras J, Paroutoglou G, et al. Migration of plastic biliary stents and endoscopic retrieval: an experience of three referral centers. Surg Laparosc Endosc Percutan Tech 2009;19:217–221.
crossref pmid
TOOLS
PDF Links  PDF Links
PubReader  PubReader
ePub Link  ePub Link
XML Download  XML Download
Full text via DOI  Full text via DOI
Download Citation  Download Citation
  Print
Share:      
METRICS
0
Crossref
0
Scopus
2,272
View
116
Download
Related articles
Black esophagus: a life-threatening adverse event associated with endoscopic retrograde cholangiopancreatography  2024 March;57(2)
Single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy: a technical review  2023 November;56(6)
Outcomes of endoscopic retrograde cholangiopancreatography in patients with situs inversus viscerum  2023 November;56(6)
Rotatable sphincterotome as a rescue device for endoscopic retrograde cholangiopancreatography cannulation: a single-center experience  2024 January;57(1)
Standardization of endoscopic ultrasound shear wave elastography  2023 March;56(2)
Editorial Office
Korean Society of Gastrointestinal Endoscopy
#817, 156 Yanghwa-ro (LG Palace, Donggyo-dong), Mapo-gu, Seoul, 04050, Korea
TEL: +82-2-335-1552   FAX: +82-2-335-2690    E-mail: CE@gie.or.kr
Copyright © Korean Society of Gastrointestinal Endoscopy.                 Developed in M2PI
Close layer