-
Feasibility and Accuracy of Transduodenal Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Solid Lesions Using a 19-Gauge Flexible Needle: A Multicenter Study
-
Germana de Nucci, Maria Chiara Petrone, Nicola Imperatore, Edoardo Forti, Roberto Grassia, Silvia Giovanelli, Laura Ottaviani, Vincenzo Mirante, Giuseppe Sabatino, Carlo Fabbri, Mauro Manno, Paolo Giorgio Arcidiacono, Gianpiero Manes
-
Clin Endosc 2021;54(2):229-235. Published online May 25, 2020
-
DOI: https://doi.org/10.5946/ce.2020.056
-
-
Abstract
PDFPubReaderePub
- Background
/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is the go-to method for obtaining samples from gastrointestinal tract and pancreatic lesions. When the transduodenal approach is utilized, the use of a more flexible needle, such as a nitinol 19-gauge (G) needle, has been recommended. The aim of this study was to evaluate the feasibility and accuracy of 19-G flexible aspiration needles in obtaining samples from solid lesions through a transduodenal approach.
Methods This was a retrospective analysis of prospectively collected data from eight Italian endoscopy centers. Consecutive patients with solid lesions who underwent transduodenal EUS-FNA with a 19-G flexible needle were included.
Results A total of 201 patients were enrolled. According to histology, EUS, radiology and 12 months of follow-up, 151 patients had malignant lesions and 50 patients had benign lesions. EUS-FNA was feasible in all cases. An adequate histologic sample was obtained in all except eight cases (96.1%). The sensitivity of EUS-FNA was 92.1% (95% confidence interval [CI], 86.8%–95.7%), and the specificity was 100% (95% CI, 90.5%–100%). The positive predictive value was 100% (95% CI, 93.4%–100%), and the negative predictive value was 74% (95% CI, 62.8%–82.7%). The diagnostic accuracy was 93.5% (95% CI, 89.2%–96.5%).
Conclusions The transduodenal approach for obtaining samples from solid lesions using a 19-G flexible needle seems feasible and accurate.
-
Citations
Citations to this article as recorded by
- Comparation of 5 ml and 10 ml Negative Pressures with Wet-suction Techniques for EUS-FNA of Solid Lesions
Yuchun Zhu, Yang Su, Peng Yang, Jiaojun Li, Tai Yu, Yi Wang, Xi Zhou, Ming Zhao, Xiaobin Sun, Jing Shan Journal of Clinical Gastroenterology.2025; 59(1): 97. CrossRef - Comparing needle types and aspiration techniques in EUS-TA to optimize diagnostic efficacy and specimen quality in patients with pancreatic lesions
Rumin Shang, Xiangming Han, Fangwei He, Lihua Huang, Cui Zeng, Kun Chen, Fei Lv, Xiangwu Ding Frontiers in Medicine.2024;[Epub] CrossRef - Diagnostic Ability of Endoscopic Ultrasound-Guided Tissue Acquisition Using 19-Gauge Fine-Needle Biopsy Needle for Abdominal Lesions
Kotaro Takeshita, Susumu Hijioka, Yoshikuni Nagashio, Yuta Maruki, Yuki Kawasaki, Kosuke Maehara, Yumi Murashima, Mao Okada, Go Ikeda, Natsumi Yamada, Tetsuro Takasaki, Daiki Agarie, Hidenobu Hara, Yuya Hagiwara, Kohei Okamoto, Daiki Yamashige, Akihiro Oh Diagnostics.2023; 13(3): 450. CrossRef - Effect of wet-heparinized suction on the quality of mediastinal solid tumor specimens obtained by endoscopic ultrasound-guided fine-needle aspiration: a retrospective study from a single center
Bo Xu, Qian Lu, Rong Fang, Xiaojuan Dai, Haiyan Xu, Xiangwu Ding, Huawei Gui BMC Gastroenterology.2023;[Epub] CrossRef - Comparison of Endoscopic Ultrasound-Guided Fine Needle Aspiration with 19-Gauge and 22-Gauge Needles for Solid Pancreatic Lesions
Changjuan Li, Jianwei Mi, Fulai Gao, Xinying Zhu, Miao Su, Xiaoli Xie, Dongqiang Zhao International Journal of General Medicine.2021; Volume 14: 10439. CrossRef
-
4,877
View
-
114
Download
-
6
Web of Science
-
5
Crossref
|