No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis
Shyam Vedantam, Rahil Shah, Sean Bhalla, Shria Kumar, Sunil Amin
Clin Endosc 2023;56(3):298-307.   Published online May 22, 2023
DOI: https://doi.org/10.5946/ce.2022.299
AbstractAbstract PDFSupplementary MaterialPubReaderePub
Background
/Aims: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction.
Methods
Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed.
Results
Thirteen studies were included. The 15 mm and 20 mm LAMS had pooled technical success rates of 93.2% (95% confidence interval [CI], 90.5%–95.2%) and 92.1% (95% CI, 68.4%–98.4%), clinical success rates of 88.6% (95% CI, 85.4%–91.1%) and 89.6% (95% CI, 79.0%–95.1%), adverse event rates of 11.4% (95% CI, 8.1%–15.9%) and 14.7% (95% CI, 4.4%–39.1%), and reintervention rates of 10.3% (95% CI, 6.7%–15.4%) and 3.5% (95% CI, 1.6%–7.6%), respectively. Subgroup analysis revealed no significant differences in technical success, clinical success, or adverse event rates. An increased need for reintervention was noted in the 15 mm stent group (pooled odds ratio, 3.59; 95% CI, 1.40–9.18; p=0.008).
Conclusions
No differences were observed in the technical, clinical, or adverse event rates between 15 and 20 mm LAMS use in EUS-GE. An increased need for reintervention is possible when using a 15 mm stent compared to when using a 20 mm stent.

Citations

Citations to this article as recorded by  
  • Endoscopic gastrointestinal bypass anastomosis using deformable self-assembled magnetic anastomosis rings (DSAMARs) in a pig model
    Miaomiao Zhang, Jianqi Mao, Jia Ma, Shuqin Xu, Yi Lyu, Xiaopeng Yan
    BMC Gastroenterology.2024;[Epub]     CrossRef
  • Revealing Insights: A Comprehensive Overview of Gastric Outlet Obstruction Management, with Special Emphasis on EUS-Guided Gastroenterostomy
    Dimitrios Ziogas, Thomas Vasilakis, Christina Kapizioni, Eleni Koukoulioti, Georgios Tziatzios, Paraskevas Gkolfakis, Antonio Facciorusso, Ioannis S. Papanikolaou
    Medical Sciences.2024; 12(1): 9.     CrossRef
  • Lumen-apposing metal stents: A primer on indications and technical tips
    Sridhar Sundaram, Suprabhat Giri, Kenneth Binmoeller
    Indian Journal of Gastroenterology.2024; 43(5): 886.     CrossRef
  • Advances in self-expandable metal stents for endoscopic ultrasound-guided interventions
    Dong Kee Jang, Dong Wook Lee, Seong-Hun Kim, Kwang Bum Cho, Sundeep Lakhtakia
    Clinical Endoscopy.2024; 57(5): 588.     CrossRef
  • Endoscopic stenting for malignant gastric outlet obstruction: focusing on comparison of endoscopic stenting and surgical gastrojejunostomy
    Sun Gyo Lim, Chan Gyoo Kim
    Clinical Endoscopy.2024; 57(5): 571.     CrossRef
  • III BRAZILIAN CONSENSUS STATEMENT ON ENDOSCOPIC ULTRASOUND
    Ricardo Rangel de Paula PESSOA, Alexandre Moraes BESTETTI, Victor Lira de OLIVEIRA, Wladimir Campos de ARAUJO, Simone GUARALDI, Rodrigo Roda RODRIGUES SILVA, Francisco Antonio Araujo OLIVEIRA, Maria Sylvia Ierardi RIBEIRO, Fred Olavo Aragão Andrade CARNEI
    Arquivos de Gastroenterologia.2024;[Epub]     CrossRef
  • The Role of Luminal Apposing Metal Stents on the Treatment of Malignant and Benign Gastric Outlet Obstruction
    Mihai Rimbaș, Kar Wai Lau, Giulia Tripodi, Gianenrico Rizzatti, Alberto Larghi
    Diagnostics.2023; 13(21): 3308.     CrossRef
  • 3,122 View
  • 123 Download
  • 5 Web of Science
  • 7 Crossref