No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis
-
Shyam Vedantam, Rahil Shah, Sean Bhalla, Shria Kumar, Sunil Amin
-
Clin Endosc 2023;56(3):298-307. Published online May 22, 2023
-
DOI: https://doi.org/10.5946/ce.2022.299
-
-
Abstract
PDFSupplementary MaterialPubReaderePub
- Background
/Aims: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction.
Methods Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed.
Results Thirteen studies were included. The 15 mm and 20 mm LAMS had pooled technical success rates of 93.2% (95% confidence interval [CI], 90.5%–95.2%) and 92.1% (95% CI, 68.4%–98.4%), clinical success rates of 88.6% (95% CI, 85.4%–91.1%) and 89.6% (95% CI, 79.0%–95.1%), adverse event rates of 11.4% (95% CI, 8.1%–15.9%) and 14.7% (95% CI, 4.4%–39.1%), and reintervention rates of 10.3% (95% CI, 6.7%–15.4%) and 3.5% (95% CI, 1.6%–7.6%), respectively. Subgroup analysis revealed no significant differences in technical success, clinical success, or adverse event rates. An increased need for reintervention was noted in the 15 mm stent group (pooled odds ratio, 3.59; 95% CI, 1.40–9.18; p=0.008).
Conclusions No differences were observed in the technical, clinical, or adverse event rates between 15 and 20 mm LAMS use in EUS-GE. An increased need for reintervention is possible when using a 15 mm stent compared to when using a 20 mm stent.
-
Citations
Citations to this article as recorded by
- Endoscopic gastrointestinal bypass anastomosis using deformable self-assembled magnetic anastomosis rings (DSAMARs) in a pig model
Miaomiao Zhang, Jianqi Mao, Jia Ma, Shuqin Xu, Yi Lyu, Xiaopeng Yan BMC Gastroenterology.2024;[Epub] CrossRef - Revealing Insights: A Comprehensive Overview of Gastric Outlet Obstruction Management, with Special Emphasis on EUS-Guided Gastroenterostomy
Dimitrios Ziogas, Thomas Vasilakis, Christina Kapizioni, Eleni Koukoulioti, Georgios Tziatzios, Paraskevas Gkolfakis, Antonio Facciorusso, Ioannis S. Papanikolaou Medical Sciences.2024; 12(1): 9. CrossRef - Lumen-apposing metal stents: A primer on indications and technical tips
Sridhar Sundaram, Suprabhat Giri, Kenneth Binmoeller Indian Journal of Gastroenterology.2024; 43(5): 886. CrossRef - Advances in self-expandable metal stents for endoscopic ultrasound-guided interventions
Dong Kee Jang, Dong Wook Lee, Seong-Hun Kim, Kwang Bum Cho, Sundeep Lakhtakia Clinical Endoscopy.2024; 57(5): 588. CrossRef - Endoscopic stenting for malignant gastric outlet obstruction: focusing on comparison of endoscopic stenting and surgical gastrojejunostomy
Sun Gyo Lim, Chan Gyoo Kim Clinical Endoscopy.2024; 57(5): 571. CrossRef - III BRAZILIAN CONSENSUS STATEMENT ON ENDOSCOPIC ULTRASOUND
Ricardo Rangel de Paula PESSOA, Alexandre Moraes BESTETTI, Victor Lira de OLIVEIRA, Wladimir Campos de ARAUJO, Simone GUARALDI, Rodrigo Roda RODRIGUES SILVA, Francisco Antonio Araujo OLIVEIRA, Maria Sylvia Ierardi RIBEIRO, Fred Olavo Aragão Andrade CARNEI Arquivos de Gastroenterologia.2024;[Epub] CrossRef - The Role of Luminal Apposing Metal Stents on the Treatment of Malignant and Benign Gastric Outlet Obstruction
Mihai Rimbaș, Kar Wai Lau, Giulia Tripodi, Gianenrico Rizzatti, Alberto Larghi Diagnostics.2023; 13(21): 3308. CrossRef
-
3,124
View
-
123
Download
-
5
Web of Science
-
7
Crossref
|