-
Hepatobiliary scintigraphy of bile excretion after endoscopic ultrasound-guided hepaticogastrostomy for malignant biliary obstruction: a retrospective study in Japan
-
Masanori Yamada, Kazuo Hara, Shin Haba, Takamichi Kuwahara, Nozomi Okuno, Yasuhiro Kuraishi, Takafumi Yanaidani, Sho Ishikawa, Tsukasa Yasuda, Toshitaka Fukui
-
Clin Endosc 2024;57(6):798-806. Published online August 20, 2024
-
DOI: https://doi.org/10.5946/ce.2023.291
-
-
Graphical Abstract
Abstract
PDFSupplementary MaterialPubReaderePub
- Background
/Aims: Hepatobiliary scintigraphy (HBS) is used to evaluate bile excretion. This study aimed to evaluate biliary excretion during endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) using HBS.
Methods We retrospectively evaluated 78 consecutive patients with malignant extrahepatic biliary obstruction, who underwent HBS after EUS-HGS between April 2015 and July 2022. The peak time and decay rate were scored with 0, 1, or 2 points based on thresholds of 20 and 35 minutes, and 10% and 50%, respectively. A total score of 4 or 3 was considered indicative of good bile excretion, whereas scores of 2, 1, or 0 indicated poor bile excretion.
Results The good and poor bile excretion groups included 40 and 38 cases, respectively. The group with good bile excretion had a significantly longer time to recurrent biliary obstruction compared to the poor bile excretion group (not reached vs. 124 days, p=0.026). Multivariate analysis identified the site of obstruction as a significant factor influencing good bile excretion (odds ratio, 3.39; 95% confidence interval, 1.01–11.4, p=0.049), with superior bile excretion observed in cases involving upper biliary obstruction compared to middle or lower biliary obstruction.
Conclusions In patients with malignant biliary obstruction who underwent HGS, the site of obstruction is significantly associated with stent patency.
-
Safety and efficacy of novel oblique-viewing scope for B2-endoscopic ultrasound-guided hepaticogastrostomy
-
Sho Ishikawa, Kazuo Hara, Nozomi Okuno, Nobumasa Mizuno, Shin Haba, Takamichi Kuwahara, Yasuhiro Kuraishi, Takafumi Yanaidani, Masanori Yamada, Tsukasa Yasuda, Toshitaka Fukui, Teru Kumagi, Yoichi Hiasa
-
Clin Endosc 2024;57(4):527-533. Published online March 29, 2024
-
DOI: https://doi.org/10.5946/ce.2023.129
-
-
Graphical Abstract
Abstract
PDFPubReaderePub
- Background
/Aims: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) performed at the intrahepatic bile duct segment 3 (B3) is widely used for biliary drainage. Although performing post-puncture procedures is easier in the intrahepatic bile duct segment 2 (B2) when using a conventional oblique-viewing (OV) EUS scope, this method may cause transesophageal puncture and severe adverse events. We evaluated the safety and efficacy of B2 puncture using a novel OV-EUS scope.
Methods In this single-center retrospective study, we prospectively enrolled and collected data from 45 patients who consecutively underwent EUS-HGS procedures with a novel OV-EUS scope between September 2021 and December 2022 at our cancer center.
Results The technical success rates of B2-EUS-HGS and EUS-HGS were 93.3% (42/45) and 97.8% (44/45), respectively. The early adverse event rate was 8.9% (4/45) with no cases of scope changes or transesophageal punctures. The median procedure time was 13 minutes (range, 5–30).
Conclusions B2-EUS-HGS can be performed safely with the novel EG-740UT (Fujifilm) OV-scope without transesophageal puncture and with a high success rate. B2-EUS-HGS using this novel OV scope may be the preferred strategy for EUS-HGS.
-
Citations
Citations to this article as recorded by
- Dedicated Echoendoscope for Interventional Endoscopic Ultrasound: Comparison with a Conventional Echoendoscope
Toshio Fujisawa, Shigeto Ishii, Yousuke Nakai, Hirofumi Kogure, Ko Tomishima, Yusuke Takasaki, Koichi Ito, Sho Takahashi, Akinori Suzuki, Hiroyuki Isayama Journal of Clinical Medicine.2024; 13(10): 2840. CrossRef
-
4,054
View
-
243
Download
-
1
Web of Science
-
1
Crossref
-
The role of needle-based confocal laser endomicroscopy in the diagnosis of pancreatic neuroendocrine tumors
-
Masanori Yamada, Kazuo Hara, Nobumasa Mizuno, Shin Haba, Takamichi Kuwahara, Nozomi Okuno, Yasuhiro Kuraishi, Takafumi Yanaidani, Sho Ishikawa, Tsukasa Yasuda, Toshitaka Fukui
-
Clin Endosc 2024;57(3):393-401. Published online September 12, 2023
-
DOI: https://doi.org/10.5946/ce.2023.068
-
-
Graphical Abstract
Abstract
PDFPubReaderePub
- Background
/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a highly accurate method for diagnosing pancreatic neuroendocrine tumors (PNETs); however, some PNETs are difficult to diagnose. Recently, the efficacy of needle-based confocal laser endomicroscopy (nCLE) in diagnosing solid pancreatic masses has been reported. However, the efficacy of nCLE in the diagnosis of PNETs remains unknown and only a small number of cases have been reported. Hence, this study aimed to evaluate the efficacy of nCLE in the diagnosis of PNETs.
Methods This single-center retrospective study evaluated 30 consecutive patients with suspected PNETs on contrast-enhanced computed tomography, who consented to nCLE combined with EUS-FNA and were diagnosed using EUS-FNA or surgical resection. The diagnostic criteria for PNETs using nCLE were based on the nesting and trabecular and glandular arrangement of tumor cell clusters surrounded by capillary vessels and fibrosis, as reported in previous studies.
Results The diagnosis using nCLE was classified into three categories: misdiagnosis in three cases (10%), non-diagnostic in six cases (20%), and diagnostic in 21 cases (70%). nCLE was able to diagnose PNET in one of the two cases with inconclusive EUS-FNA.
Conclusions Although further development of the resolution and optimization of the diagnostic criteria are required, nCLE may constitute a useful diagnostic option in cases of inconclusive EUS-FNA for PNETs.
-
Citations
Citations to this article as recorded by
- Recent developments in the diagnosis of pancreatic neuroendocrine neoplasms
Anna Battistella, Matteo Tacelli, Paola Mapelli, Marco Schiavo Lena, Valentina Andreasi, Luana Genova, Francesca Muffatti, Francesco De Cobelli, Stefano Partelli, Massimo Falconi Expert Review of Gastroenterology & Hepatology.2024; 18(4-5): 155. CrossRef - Advancements and challenges in gastrointestinal imaging
Eun Jeong Gong, Chang Seok Bang World Journal of Clinical Cases.2024; 12(33): 6591. CrossRef
-
2,788
View
-
129
Download
-
1
Web of Science
-
2
Crossref
-
Clinical utility of endoscopic ultrasound-guided tissue acquisition for comprehensive genomic profiling of patients with biliary tract cancer, especially with intrahepatic cholangiocarcinoma
-
Takafumi Yanaidani, Kazuo Hara, Nozomi Okuno, Shin Haba, Takamichi Kuwahara, Yasuhiro Kuraishi, Nobumasa Mizuno, Sho Ishikawa, Masanori Yamada, Tsukasa Yasuda
-
Clin Endosc 2024;57(3):384-392. Published online February 15, 2024
-
DOI: https://doi.org/10.5946/ce.2023.139
-
-
Graphical Abstract
Abstract
PDFPubReaderePub
- Background
/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is a standard diagnostic method for biliary tract cancer (BTC), and samples obtained in this manner may be used for comprehensive genomic profiling (CGP). This study evaluated the utility of EUS-TA for CGP in a clinical setting and determined the factors associated with the adequacy of CGP in patients with BTC.
Methods CGP was attempted for 105 samples from 94 patients with BTC at the Aichi Cancer Center, Japan, from October 2019 to April 2022.
Results Overall, 77.1% (81/105) of the samples were adequate for CGP. For 22-G or 19-G fine-needle biopsy (FNB), the sample adequacy was 85.7% (36/42), which was similar to that of surgical specimens (94%, p=0.45). Univariate analysis revealed that 22-G or larger FNB needle usage (86%, p=0.003), the target primary lesions (88%, p=0.015), a target size ≥30 mm (100%, p=0.0013), and number of punctures (90%, p=0.016) were significantly positively associated with CGP sample adequacy.
Conclusions EUS-TA is useful for CGP tissue sampling in patients with BTC. In particular, the use of 22-G or larger FNB needles may allow for specimen adequacy comparable to that of surgical specimens.
-
Citations
Citations to this article as recorded by
- Is genomic analysis possible in a tissue acquired via endoscopic ultrasound-guided fine-needle biopsy in cholangiocarcinoma?
Jonghyun Lee, Sung Yong Han Clinical Endoscopy.2024; 57(3): 332. CrossRef - Utility of Transpapillary Biopsy and Endoscopic Ultrasound-Guided Tissue Acquisition for Comprehensive Genome Profiling of Unresectable Biliary Tract Cancer
Soma Fukuda, Susumu Hijioka, Yoshikuni Nagashio, Daiki Yamashige, Daiki Agarie, Yuya Hagiwara, Kohei Okamoto, Shin Yagi, Yasuhiro Komori, Masaru Kuwada, Yuta Maruki, Chigusa Morizane, Hideki Ueno, Nobuyoshi Hiraoka, Kiichiro Tsuchiya, Takuji Okusaka Cancers.2024; 16(16): 2819. CrossRef - Endoscopic Ultrasound and Intraductal Ultrasound in the Diagnosis of Biliary Tract Diseases: A Narrative Review
Akiya Nakahata, Yasunobu Yamashita, Masayuki Kitano Diagnostics.2024; 14(18): 2086. CrossRef
-
2,716
View
-
76
Download
-
3
Web of Science
-
3
Crossref
-
Safety of endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction and ascites
-
Tsukasa Yasuda, Kazuo Hara, Nobumasa Mizuno, Shin Haba, Takamichi Kuwahara, Nozomi Okuno, Yasuhiro Kuraishi, Takafumi Yanaidani, Sho Ishikawa, Masanori Yamada, Toshitaka Fukui
-
Clin Endosc 2024;57(2):246-252. Published online September 7, 2023
-
DOI: https://doi.org/10.5946/ce.2023.075
-
-
Graphical Abstract
Abstract
PDFSupplementary MaterialPubReaderePub
- Background
/Aims: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) is useful for patients with biliary cannulation failure or inaccessible papillae. However, it can lead to serious complications such as bile peritonitis in patients with ascites; therefore, development of a safe method to perform EUS-HGS is important. Herein, we evaluated the safety of EUS-HGS with continuous ascitic fluid drainage in patients with ascites.
Methods Patients with moderate or severe ascites who underwent continuous ascites drainage, which was initiated before EUS-HGS and terminated after the procedure at our institution between April 2015 and December 2022, were included in the study. We evaluated the technical and clinical success rates, EUS-HGS-related complications, and feasibility of re-intervention.
Results Ten patients underwent continuous ascites drainage, which was initiated before EUS-HGS and terminated after completion of the procedure. Median duration of ascites drainage before and after EUS-HGS was 2 and 4 days, respectively. Technical success with EUS-HGS was achieved in all 10 patients (100%). Clinical success with EUS-HGS was achieved in 9 of the 10 patients (90 %). No endoscopic complications such as bile peritonitis were observed.
Conclusions In patients with ascites, continuous ascites drainage, which is initiated before EUS-HGS and terminated after completion of the procedure, may prevent complications and allow safe performance of EUS-HGS.
-
Citations
Citations to this article as recorded by
- Management of iatrogenic perforations during endoscopic interventions in the hepato-pancreatico-biliary tract
Kirsten Boonstra, Rogier P. Voermans, Roy L.J. van Wanrooij Best Practice & Research Clinical Gastroenterology.2024; 70: 101890. CrossRef - Is Endoscopic Ultrasound-Guided Hepaticogastrostomy Safe and Effective after Failed Endoscopic Retrograde Cholangiopancreatography?—A Systematic Review and Meta-Analysis
Saqr Alsakarneh, Mahmoud Y. Madi, Dushyant Singh Dahiya, Fouad Jaber, Yassine Kilani, Mohamed Ahmed, Azizullah Beran, Mohamed Abdallah, Omar Al Ta’ani, Anika Mittal, Laith Numan, Hemant Goyal, Mohammad Bilal, Wissam Kiwan Journal of Clinical Medicine.2024; 13(13): 3883. CrossRef - Feasibility and safety of EUS-guided biliary drainage in inexperienced centers: a multicenter study in southwest Japan
Takehiko Koga, Yusuke Ishida, Shunpei Hashigo, Yuzo Shimokawa, Hirofumi Harima, Kazuhisa Okamoto, Akihisa Ohno, Tsukasa Miyagahara, Toshihiro Fujita, Satoshi Fukuchi, Kosuke Takahashi, Hiroki Taguchi, Norimasa Araki, Yuichiro Ohtsuka, Toshiyuki Uekitani, Gastrointestinal Endoscopy.2024;[Epub] CrossRef - Endoscopic ultrasound-guided antegrade stenting combined with closure of the puncture route using self-assembling peptide solution in a jaundiced patient with ascites
Hirotsugu Maruyama, Kojiro Tanoue, Tatsuya Kurokawa, Yoshinori Shimamoto, Yuki Ishikawa-Kakiya, Akira Higashimori, Yasuhiro Fujiwara Endoscopy.2024; 56(S 01): E953. CrossRef
-
3,447
View
-
199
Download
-
4
Web of Science
-
4
Crossref
-
Refractory benign biliary stricture due to chronic pancreatitis in two patients treated using endoscopic ultrasound-guided choledochoduodenostomy fistula creation: case reports
-
Sho Ishikawa, Nozomi Okuno, Kazuo Hara, Nobumasa Mizuno, Shin Haba, Takamichi Kuwahara, Yasuhiro Kuraishi, Takafumi Yanaidani
-
Clin Endosc 2024;57(1):122-127. Published online May 16, 2023
-
DOI: https://doi.org/10.5946/ce.2022.149
-
-
Abstract
PDFPubReaderePub
- Benign biliary stricture (BBS) is a complication of chronic pancreatitis (CP). Despite endoscopic biliary stenting, some patients do not respond to treatment, and they experience recurrent cholangitis. We report two cases of CP with refractory BBS treated using endoscopic ultrasound-guided choledochoduodenostomy (EUS-CDS) fistula creation. A 50-year-old woman and a 60-year-old man both presented with obstructive jaundice secondary to BBS due to alcoholic CP. They underwent repeated placement of a fully covered self-expandable metal stent for biliary strictures. However, the strictures persisted, causing repeated episodes of cholangitis. Therefore, an EUS-CDS was performed. The stents were eventually removed and the patients became stent-free. These fistulas have remained patent without cholangitis for more than 2.5 years. Fistula creation using EUS-CDS is an effective treatment option for BBS.
-
Citations
Citations to this article as recorded by
- Forward viewing liner echoendoscopy for therapeutic interventions
Kazuo Hara, Nozomi Okuno, Shin Haba, Takamichi Kuwahara Clinical Endoscopy.2024; 57(2): 175. CrossRef - Successful sequential management of traumatic choledochal leak and stenosis in children using ERCP: a case report and literature review
Cuo Leng, Yu Zou, Zhoujian Yang, Xinhua Zhao Frontiers in Medicine.2024;[Epub] CrossRef
-
2,288
View
-
168
Download
-
2
Web of Science
-
2
Crossref
-
Safety and feasibility of opening window fistulotomy as a new precutting technique for primary biliary access in endoscopic retrograde cholangiopancreatography
-
Yasuhiro Kuraishi, Kazuo Hara, Shin Haba, Takamichi Kuwahara, Nozomi Okuno, Takafumi Yanaidani, Sho Ishikawa, Tsukasa Yasuda, Masanori Yamada, Nobumasa Mizuno
-
Clin Endosc 2023;56(4):490-498. Published online April 27, 2023
-
DOI: https://doi.org/10.5946/ce.2022.130
-
-
Graphical Abstract
Abstract
PDFSupplementary MaterialPubReaderePub
- Background
/Aims: Post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) is the most common and serious complication of endoscopic retrograde cholangiopancreatography. To prevent this event, a unique precutting method, termed opening window fistulotomy, was performed in patients with a large infundibulum as the primary procedure for biliary cannulation, whereby a suprapapillary laid-down H-shaped incision was made without touching the orifice. This study aimed to assess the safety and feasibility of this novel technique.
Methods One hundred and ten patients were prospectively enrolled in this study. Patients with a papillary roof size ≥10 mm underwent opening window fistulotomy for primary biliary access. In addition, the incidence of complications and success rate of biliary cannulation were evaluated.
Results The median size of the papillary roof was 6 mm (range, 3–20 mm). Opening window fistulotomy was performed in 30 patients (27.3%), none of whom displayed PEP. Duodenal perforation was recorded in one patient (3.3%), which was resolved by conservative treatment. The cannulation rate was high (96.7%, 29/30 patients). The median duration of biliary access was 8 minutes (range, 3–15 minutes).
Conclusions Opening window fistulotomy demonstrated its feasibility for primary biliary access by achieving great safety with no PEP complications and a high success rate for biliary cannulation.
-
Citations
Citations to this article as recorded by
- Comments on ‘Safety and feasibility of opening window fistulotomy as a new precutting technique for primary biliary access in endoscopic retrograde cholangiopancreatography’
Masood Muhammad Karim, Adeel Ur Rehman, Faisal Wasim Ismail, Om Parkash Clinical Endoscopy.2024; 57(2): 280. CrossRef
-
3,376
View
-
149
Download
-
1
Web of Science
-
1
Crossref
-
Clinical utility of endoscopic ultrasound-guided tissue acquisition for comprehensive genomic profiling of pancreatic cancer
-
Nozomi Okuno, Kazuo Hara, Nobumasa Mizuno, Shin Haba, Takamichi Kuwahara, Yasuhiro Kuraishi, Daiki Fumihara, Takafumi Yanaidani
-
Clin Endosc 2023;56(2):221-228. Published online March 7, 2023
-
DOI: https://doi.org/10.5946/ce.2022.086
-
-
Abstract
PDFPubReaderePub
- Background
/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is essential for the diagnosis of pancreatic cancer. The feasibility of comprehensive genomic profiling (CGP) using samples obtained by EUS-TA has been under recent discussion. This study aimed to evaluate the utility of EUS-TA for CGP in a clinical setting.
Methods CGP was attempted in 178 samples obtained from 151 consecutive patients with pancreatic cancer at the Aichi Cancer Center between October 2019 and September 2021. We evaluated the adequacy of the samples for CGP and determined the factors associated with the adequacy of the samples obtained by EUS-TA retrospectively.
Results The overall adequacy for CGP was 65.2% (116/178), which was significantly different among the four sampling methods (EUS-TA vs. surgical specimen vs. percutaneous biopsy vs. duodenal biopsy, 56.0% [61/109] vs. 80.4% [41/51] vs. 76.5% [13/17] vs. 100.0% [1/1], respectively; p=0.022). In a univariate analysis, needle gauge/type was associated with adequacy (22 G fine-needle aspiration vs. 22 G fine-needle biopsy [FNB] vs. 19 G-FNB, 33.3% (5/15) vs. 53.5% (23/43) vs. 72.5% (29/40); p=0.022). The sample adequacy of 19 G-FNB for CGP was 72.5% (29/40), and there was no significant difference between 19 G-FNB and surgical specimens (p=0.375).
Conclusions To obtain adequate samples for CGP with EUS-TA, 19 G-FNB was shown to be the best in clinical practice. However, 19 G-FNB was not still sufficient, so further efforts are required to improve adequacy for CGP.
-
Citations
Citations to this article as recorded by
- Updated techniques and evidence for endoscopic ultrasound‐guided tissue acquisition from solid pancreatic lesions
Masahiro Itonaga, Reiko Ashida, Masayuki Kitano DEN Open.2025;[Epub] CrossRef - Tissue acquisition for comprehensive genomic profiling of gallbladder cancer using a forward-viewing echoendoscope in a patient who underwent Roux-en-Y reconstruction
Michihiro Ono, Shutaro Oiwa, Atsushi Uesugi, Seiya Saito, Ryota Yokoyama, Makoto Usami, Tomoyuki Abe, Miri Fujita, Kohichi Takada, Masahiro Maeda Clinical Journal of Gastroenterology.2024; 17(1): 164. CrossRef - Endoscopic ultrasound-guided tissue acquisition for comprehensive genomic profiling
Nozomi Okuno, Kazuo Hara Journal of Medical Ultrasonics.2024; 51(2): 253. CrossRef - Oil blotting paper for formalin fixation increases endoscopic ultrasound‐guided tissue acquisition‐collected sample volumes on glass slides
Takuo Yamai, Kenji Ikezawa, Yusuke Seiki, Ko Watsuji, Yasuharu Kawamoto, Takeru Hirao, Kazuma Daiku, Shingo Maeda, Makiko Urabe, Yugo Kai, Ryoji Takada, Kaori Mukai, Tasuku Nakabori, Hiroyuki Uehara, Sayoko Tsuzaki, Ayumi Ryu, Satoshi Tanada, Shigenori Na Cancer Medicine.2024;[Epub] CrossRef - Utility of Transpapillary Biopsy and Endoscopic Ultrasound-Guided Tissue Acquisition for Comprehensive Genome Profiling of Unresectable Biliary Tract Cancer
Soma Fukuda, Susumu Hijioka, Yoshikuni Nagashio, Daiki Yamashige, Daiki Agarie, Yuya Hagiwara, Kohei Okamoto, Shin Yagi, Yasuhiro Komori, Masaru Kuwada, Yuta Maruki, Chigusa Morizane, Hideki Ueno, Nobuyoshi Hiraoka, Kiichiro Tsuchiya, Takuji Okusaka Cancers.2024; 16(16): 2819. CrossRef - Mcl-1 expression is a predictive marker of response to gemcitabine plus nab-paclitaxel for metastatic pancreatic cancer
Makiko Urabe, Kenji Ikezawa, Yusuke Seiki, Ko Watsuji, Yasuharu Kawamoto, Takeru Hirao, Yugo Kai, Ryoji Takada, Takuo Yamai, Kaori Mukai, Tasuku Nakabori, Hiroyuki Uehara, Shigenori Nagata, Kazuyoshi Ohkawa Scientific Reports.2024;[Epub] CrossRef - Endoscopic ultrasound-guided tissue acquisition for personalized treatment in pancreatic adenocarcinoma
Sang Myung Woo Clinical Endoscopy.2023; 56(2): 183. CrossRef - Comparison of the novel Franseen needle versus the fine‐needle aspiration needle in endoscopic ultrasound‐guided tissue acquisition for cancer gene panel testing: A propensity score‐matching analysis
Tomotaka Mori, Eisuke Ozawa, Akane Shimakura, Kosuke Takahashi, Satoshi Matsuo, Kazuaki Tajima, Yasuhiko Nakao, Masanori Fukushima, Ryu Sasaki, Satoshi Miuma, Hisamitsu Miyaaki, Shinji Okano, Kazuhiko Nakao JGH Open.2023; 7(9): 652. CrossRef - Editorial: Endoscopic ultrasound‐guided tissue acquisition in the era of precision medicine
Tiing Leong Ang, James Weiquan Li, Lai Mun Wang Journal of Gastroenterology and Hepatology.2023; 38(10): 1677. CrossRef
-
2,593
View
-
178
Download
-
8
Web of Science
-
9
Crossref
|