Skip Navigation
Skip to contents

Clin Endosc : Clinical Endoscopy

OPEN ACCESS

Author index

Page Path
HOME > Browse articles > Author index
Search
Yong Sik Kim 2 Articles
Feasibility of Obtaining Quantitative 3-Dimensional Information Using Conventional Endoscope: A Pilot Study
Jong Jin Hyun, Hoon Jai Chun, Bora Keum, Yeon Seok Seo, Yong Sik Kim, Yoon Tae Jeen, Hong Sik Lee, Soon Ho Um, Chang Duck Kim, Ho Sang Ryu, Jong-Wook Lim, Dong-Gi Woo, Young-Joong Kim, Myo-Taeg Lim
Clin Endosc 2012;45(3):182-188.   Published online August 22, 2012
DOI: https://doi.org/10.5946/ce.2012.45.3.182
AbstractAbstract PDFPubReaderePub
Background/Aims

Three-dimensional (3D) imaging is gaining popularity and has been partly adopted in laparoscopic surgery or robotic surgery but has not been applied to gastrointestinal endoscopy. As a first step, we conducted an experiment to evaluate whether images obtained by conventional gastrointestinal endoscopy could be used to acquire quantitative 3D information.

Methods

Two endoscopes (GIF-H260) were used in a Borrmann type I tumor model made of clay. The endoscopes were calibrated by correcting the barrel distortion and perspective distortion. Obtained images were converted to gray-level image, and the characteristics of the images were obtained by edge detection. Finally, data on 3D parameters were measured by using epipolar geometry, two view geometry, and pinhole camera model.

Results

The focal length (f) of endoscope at 30 mm was 258.49 pixels. Two endoscopes were fixed at predetermined distance, 12 mm (d12). After matching and calculating disparity (v2-v1), which was 106 pixels, the calculated length between the camera and object (L) was 29.26 mm. The height of the object projected onto the image (h) was then applied to the pinhole camera model, and the result of H (height and width) was 38.21 mm and 41.72 mm, respectively. Measurements were conducted from 2 different locations. The measurement errors ranged from 2.98% to 7.00% with the current Borrmann type I tumor model.

Conclusions

It was feasible to obtain parameters necessary for 3D analysis and to apply the data to epipolar geometry with conventional gastrointestinal endoscope to calculate the size of an object.

Citations

Citations to this article as recorded by  
  • Three-dimensional light-field microendoscopy with a GRIN lens array
    Tara M. Urner, Andrew Inman, Benjamin Lapid, Shu Jia
    Biomedical Optics Express.2022; 13(2): 590.     CrossRef
  • 3D light-field endoscopic imaging using a GRIN lens array
    Changliang Guo, Tara Urner, Shu Jia
    Applied Physics Letters.2020;[Epub]     CrossRef
  • Current and emerging robotic assisted intervention for Notes
    Siyang Zuo, Shuxin Wang
    Expert Review of Medical Devices.2016; 13(12): 1095.     CrossRef
  • Application of robotics in gastrointestinal endoscopy: A review
    Baldwin Po Man Yeung
    World Journal of Gastroenterology.2016; 22(5): 1811.     CrossRef
  • Quantitative analysis of velopharyngeal movement using a stereoendoscope: accuracy and reliability of range images
    Asuka Nakano, Katsuaki Mishima, Ruriko Shiraishi, Yoshiya Ueyama
    Computer Aided Surgery.2015; 20(1): 29.     CrossRef
  • The Evolution of the Conventional Endoscope in an Era of 3-Dimensional Technology
    Geun Am Song
    Clinical Endoscopy.2012; 45(3): 181.     CrossRef
  • 6,302 View
  • 71 Download
  • 6 Crossref
Close layer
Comparison on the Efficacy of Disinfectants Used in Automated Endoscope Reprocessors: PHMB-DBAC versus Orthophthalaldehyde
Sun Young Kim, Hong Sik Lee, Jong Jin Hyun, Min Ho Seo, Sun Young Yim, Ha Young Oh, Hye Sook Kim, Bora Keum, Yeon Seok Seo, Yong Sik Kim, Yoon Tae Jeen, Hoon Jai Chun, Soon Ho Um, Chang Duck Kim, Ho Sang Ryu
Clin Endosc 2011;44(2):109-115.   Published online December 31, 2011
DOI: https://doi.org/10.5946/ce.2011.44.2.109
AbstractAbstract PDFPubReaderePub
Background/Aims

Since endoscopes are reusable apparatus classified as semicritical item, thorough reprocessing to achieve high-level disinfection is of utmost importance to prevent spread of infection. To improve disinfection efficacy and safety, disinfectants and endoscope reprocessors are continuously evolving. This study aimed to compare the efficacy of the combination of polyhexamethylenebiguanide hydrochloride-alkyldimethylbenzylammonium chloride (PHMB-DBAC) and orthophthalaldehyde (OPA) used respectively in ultrasonographic cleaning incorporated automated endoscope reprocessors: COOLENDO (APEX Korea) or OER-A (Olympus Optical).

Methods

A total of 86 flexible upper endoscopes were randomly reprocessed with either COOLENDO/PHMB-DBAC or OER-A/OPA. Culture samplings were done at two sites (endoscope tip and working channel) which were later incubated on blood agar plate. Bacterial colonies were counted and identified.

Results

The culture-positive rate at the endoscope tip and working channel was 0% and 2.33% for COOLENDO/PHMB-DBAC and 4.65% and 0% for OER-A/OPA. Staphylococcus hominis was cultured from one endoscope reprocessed with COOLENDO/PHMB-DBAC and Pseudomonas putida was isolated from two endoscopes reprocessed with OER-A/OPA.

Conclusions

The reprocessing efficacy of COOLENDO/PHMB-DBAC was non-inferior to that of OER-A/OPA (p=0.032; confidence interval, -0.042 to 0.042). During the study period, significant side effect of PHMB-DBAC was not observed.

Citations

Citations to this article as recorded by  
  • Recommendations and guidelines for endoscope reprocessing: Current position statement of digestive endoscopic society of Taiwan
    Wei-Kuo Chang, Chen-Ling Peng, Yen-Wei Chen, Cheuk-Kay Sun, Chieh-Chang Chen, Tao-Chieh Liu, Yin-Yi Chu, I-Fang Tsai, Chen-Shuan Chung, Hsiao-Fen Lin, Fang-Yu Hsu, Wei-Chen Tai, Hsi-Chang Lee, Hsu-Heng Yen, E-Ming Wang, Shu-Hui Chen, Cheng-Hsin Chu, Ming-
    Journal of Microbiology, Immunology and Infection.2024; 57(2): 211.     CrossRef
  • Antibacterial Activity of Tannic Acid and Tannic Acid/Amphiphilic Cationic Polymer Mixtures
    Fatimah M. Alzahrani, Stephen G. Yeates, Michelle Webb, Hind Ali Alghamdi
    Asian Journal of Chemistry.2020; 32(6): 1491.     CrossRef
  • Antibacterial activity of Staphylococcus aureus biofilm under combined exposure of glutaraldehyde, near-infrared light, and 405-nm laser
    Van Nam Tran, Chakradhar Dasagrandhi, Van Gia Truong, Young-Mog Kim, Hyun Wook Kang, Michael R. Hamblin
    PLOS ONE.2018; 13(8): e0202821.     CrossRef
  • Comparison of the efficacy of disinfectants in automated endoscope reprocessors for colonoscopes: tertiary amine compound (Sencron2®) versus ortho-phthalaldehyde (Cidex®OPA)
    Hyun Il Seo, Dae Sung Lee, Eun Mi Yoon, Min-Jung Kwon, Hyosoon Park, Yoon Suk Jung, Jung Ho Park, Chong Il Sohn, Dong Il Park
    Intestinal Research.2016; 14(2): 178.     CrossRef
  • Role of Clinical Endoscopy in Emphasizing Endoscope Disinfection
    Ji Kon Ryu, Eun Young Kim, Kwang An Kwon, Il Ju Choi, Ki Baik Hahm
    Clinical Endoscopy.2015; 48(5): 351.     CrossRef
  • Recent Update of Gastrointestinal Endoscope Reprocessing
    Kyong Hee Hong, Yun Jeong Lim
    Clinical Endoscopy.2013; 46(3): 267.     CrossRef
  • Steps of Reprocessing and Equipments
    Yong Kook Lee, Jeong Bae Park
    Clinical Endoscopy.2013; 46(3): 274.     CrossRef
  • The antibiofilm effects of Byotrol™ G32
    N. Govindji, P. Wills, M. Upton, N. Tirelli, S. Yeates, M. Webb
    Journal of Applied Microbiology.2013; 114(5): 1285.     CrossRef
  • 8,525 View
  • 68 Download
  • 8 Crossref
Close layer

Clin Endosc : Clinical Endoscopy Twitter Facebook
Close layer
TOP