Skip Navigation
Skip to contents

Clin Endosc : Clinical Endoscopy

OPEN ACCESS

Search

Page Path
HOME > Search
2 "Gwangil Kim"
Filter
Filter
Article category
Keywords
Publication year
Authors
Brief Report
An Unusual Mimicker of a Pancreatic Pseudocyst
Sang Ah Choi, Chang-Il Kwon, Gwangil Kim, Daejung Kim, Sung Hoon Choi
Clin Endosc 2018;51(3):304-305.   Published online March 22, 2018
DOI: https://doi.org/10.5946/ce.2017.160
PDFPubReaderePub
  • 4,856 View
  • 125 Download
Close layer
Original Article
Endoscopic Submucosal Dissection Using a Novel Versatile Knife: An Animal Feasibility Study (with Video)
Chang-Il Kwon, Gwangil Kim, Il-Kwun Chung, Won Hee Kim, Kwang Hyun Ko, Sung Pyo Hong, Seok Jeong, Don Haeng Lee
Clin Endosc 2014;47(6):544-554.   Published online November 30, 2014
DOI: https://doi.org/10.5946/ce.2014.47.6.544
AbstractAbstract PDFSupplementary MaterialPubReaderePub
Background/Aims

In order to reduce the procedure time and the number of accessory changes during endoscopic submucosal dissection (ESD), we developed a novel versatile knife, which has the combined advantages of several conventional knives. The aim of this study was to compare the efficacy, safety, and histological quality of ESD performed using this novel versatile knife and a combination of several conventional knives.

Methods

This was an in vivo animal study comparing two different modalities of ESD in mini-pigs. Completion time of each resection was documented, and the resected specimens were retrieved and evaluated for completeness. To assess the quality control of the procedures and adverse events, detailed histopathological examinations were performed.

Results

A total of 18 specimens were dissected by ESD safely and easily (nine specimens using the new versatile knife; nine specimens by mixing conventional knives). All resections were completed as en bloc resections. There was no significant difference in procedure time between the 2 modalities (456 seconds vs. 355 seconds, p=0.258) and cutting speed (1.983 mm2/sec vs. 1.57 mm2/sec, p=1.000). The rate of adverse events and histological quality did not statistically differ between the modalities.

Conclusions

ESD with a versatile knife appeared to be an easy, safe, and technically efficient method.

Citations

Citations to this article as recorded by  
  • Comparison of synchronous dual wavelength diode laser versus conventional endo-knives for esophageal endoscopic submucosal dissection: an animal study
    Jian Tang, Shufang Ye, Xueliang Ji, Jun Li, Feng Liu
    Surgical Endoscopy.2018; 32(12): 5037.     CrossRef
  • Technological review on endoscopic submucosal dissection: available equipment, recent developments and emerging techniques
    Georgios Mavrogenis, Juergen Hochberger, Pierre Deprez, Morteza Shafazand, Dimitri Coumaros, Katsumi Yamamoto
    Scandinavian Journal of Gastroenterology.2017; 52(4): 486.     CrossRef
  • 8,119 View
  • 76 Download
  • 3 Web of Science
  • 2 Crossref
Close layer

Clin Endosc : Clinical Endoscopy Twitter Facebook
Close layer
TOP