Skip Navigation
Skip to contents

Clin Endosc : Clinical Endoscopy

OPEN ACCESS

Search

Page Path
HOME > Search
1 "Dogs"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Article
Histological Changes in the Bile Duct after Long-Term Placement of a Fully Covered Self-Expandable Metal Stent within a Common Bile Duct: A Canine Study
Sang Soo Lee, Tae Jun Song, Mee Joo, Do Hyun Park, Dong Wan Seo, Sung Koo Lee, Myung-Hwan Kim
Clin Endosc 2014;47(1):84-93.   Published online January 24, 2014
DOI: https://doi.org/10.5946/ce.2014.47.1.84
AbstractAbstract PDF
Background/Aims

To date, it has been difficult to determine the optimal stenting duration of a fully covered self-expandable metal stent (FCSEMS) in a benign biliary stricture. The purpose of this study was to identify the histopathological changes in a bile duct resulting from long-term placement of a FCSEMS.

Methods

An FCSEMS was inserted into the common bile duct of 12 canines, and the animals were divided into four groups. Posteuthanasia, necropsy was performed to examine the histopathological changes in the bile ducts after 1, 3, 6, and 9 months.

Results

The results of necropsy showed that the covered membranes of the FCSEMSs were intact and easily removed from the bile ducts in 11 of the canines. Severe epithelial hyperplasia of the stented bile duct and epithelial ingrowth into the stent occurred in one animal (from the 3-month group). On histopathological examination, mild inflammatory changes were observed in the stented bile ducts, and there was no significant difference between the four groups. Among the 12 animals, five had de novo stricture.

Conclusions

An FCSEMS can be inserted into the bile duct without severe histopathological changes up until 9 months. However, a de novo stricture and severe epithelial hyperplasia relating to the stent insertion might occur.

Citations

Citations to this article as recorded by  
  • Benign Biliary Strictures, Leaks, and Stones: Clinical Application of Retrievable Fully Covered Self-Expandable Metallic Biliary Stent with an Alternative Retrieval String Fixation Method
    Ramazan Kutlu, Nurullah Dag, Eldiiar Saparbekov, Sezai Yilmaz
    Journal of Vascular and Interventional Radiology.2026; 37(5): 108551.     CrossRef
  • Prevention of stent migration of covered self-expandable metal stents in distal malignant biliary obstruction: a review of literature
    Jung Won Chun, Woo Hyun Paik, Sang Myung Woo, Jin Ho Choi, In Rae Cho, Woo Jin Lee, Ji Kon Ryu, Yong-Tae Kim, Sang Hyub Lee
    Gastroenterology Report.2025;[Epub]     CrossRef
  • Application of Self‐Expandable Metal Stent in Dogs and Cats for the Management of Extrahepatic Biliary Obstruction: 13 Cases (2021–2024)
    Suh Hyun Chai, Kyuseok Choi, Sungin Lee, Yongsun Kim
    Veterinary Medicine and Science.2025;[Epub]     CrossRef
  • Clinical use of uncovered balloon‐expandable metallic biliary stents for treatment of extrahepatic biliary tract obstructions in cats and dogs: 11 cases (2012–2022)
    Julia L. Bergen, Blake M. Travis, Fred S. Pike
    Veterinary Surgery.2024; 53(2): 320.     CrossRef
  • Feasibility of in vivo swine models using guide wire-assisted intraductal radiofrequency ablation for benign biliary stricture
    Jae Keun Park, Ju-Il Yang, Joo Kyung Park, Kwang Hyuck Lee, Jong Kyun Lee, Kyu Taek Lee
    Scientific Reports.2023;[Epub]     CrossRef
  • Outcomes of double-layer continuous suture hepaticojejunostomy in pancreatoduodenectomy and total pancreatectomy
    Niccolò Napoli, Emanuele F. Kauffmann, Rosilde Caputo, Michael Ginesini, Fabio Asta, Cesare Gianfaldoni, Gabriella Amorese, Fabio Vistoli, Ugo Boggi
    HPB.2022; 24(10): 1738.     CrossRef
  • Controversial issues of biliary stenting in patients with proximal biliary obstruction
    J. V. Kulezneva, O. V. Melekhina, A. B. Musatov, M. G. Efanov, V. V. Tsvirkun, I. Yu. Nedoluzhko, K. V. Shishin, K. K. Salnikov, D. F. Kantimerov
    Annaly khirurgicheskoy gepatologii = Annals of HPB Surgery.2021; 26(3): 79.     CrossRef
  • A systematic review of biodegradable biliary stents: promising biocompatibility without stent removal
    Antti Siiki, Juhani Sand, Johanna Laukkarinen
    European Journal of Gastroenterology & Hepatology.2018; 30(8): 813.     CrossRef
  • Novel flower-type covered metal stent to prevent cholecystitis: experimental study in a pig model
    Young Sik Woo, Kwang Hyuck Lee, Jong Kyun Lee, Dong Hyo Noh, Joo Kyung Park, Kyu Taek Lee, Kee-Taek Jang
    Surgical Endoscopy.2016; 30(3): 1141.     CrossRef
  • Biodegradable biliary stents have a different effect than covered metal stents on the expression of proteins associated with tissue healing in benign biliary strictures
    Antti Siiki, Ralf Jesenofsky, Matthias Löhr, Isto Nordback, Minna Kellomäki, Heidi Gröhn, Joonas Mikkonen, Juhani Sand, Johanna Laukkarinen
    Scandinavian Journal of Gastroenterology.2016; 51(7): 880.     CrossRef
  • Fabrication of a silver particle-integrated silicone polymer-covered metal stent against sludge and biofilm formation and stent-induced tissue inflammation
    Tae Hoon Lee, Bong Seok Jang, Min Kyo Jung, Chan Gi Pack, Jun-Ho Choi, Do Hyun Park
    Scientific Reports.2016;[Epub]     CrossRef
  • Metal Stenting in Benign Biliary Strictures
    Ji Kon Ryu
    Clinical Endoscopy.2014; 47(1): 5.     CrossRef
  • Best endoscopic stents for the biliary tree and pancreas
    Todd H. Baron
    Current Opinion in Gastroenterology.2014; 30(5): 453.     CrossRef
  • 12,616 View
  • 112 Download
  • 13 Web of Science
  • 13 Crossref
Close layer

Clin Endosc : Clinical Endoscopy Twitter Facebook
Close layer
TOP