Skip Navigation
Skip to contents

Clin Endosc : Clinical Endoscopy

OPEN ACCESS

Search

Page Path
HOME > Search
8 "Monitoring"
Filter
Filter
Article category
Keywords
Publication year
Authors
Funded articles
Original Articles
Impact of opioid addition on procedural conditions during colonoscopy: a randomized trial comparing propofol-based sedation protocols
David Novotny, Jan Palenik, Tomas Tyll, Nadija Brodyuk, Stepan Suchanek, Michal Sotak
Clin Endosc 2025;58(5):722-730.   Published online July 4, 2025
DOI: https://doi.org/10.5946/ce.2024.347
Graphical AbstractGraphical Abstract AbstractAbstract PDF
Background
/Aims: Propofol is the most effective sedative for colonoscopy; however, opioids do have several adverse effects that need to be discussed. The objective of this study was to compare the ease of colonoscopy during propofol-based sedation with and without fentanyl, while closely monitoring ventilatory data and the safety of the procedure.
Methods
This prospective single-center trial randomized 50 patients who underwent minor colonoscopies. The propofol group received sedation exclusively via propofol, whereas the propofol+fentanyl group was premedicated with 1 µg/kg fentanyl. Patients were monitored using a bioimpedance ventilatory monitor, and both the patients and endoscopists were questioned regarding their level of satisfaction.
Results
The endoscopists reported a higher level of ease with the colonoscopy procedure (mean on a 5-point scale, 1.2 vs. 1.72; p=0.028) and the overall patient satisfaction score was higher (1.15 vs. 1.28, p=0.026) in the propofol+fentanyl group. No significant differences were observed in the ventilatory parameters between the groups. No major adverse events were reported in any of the groups.
Conclusions
The inclusion of fentanyl leads to enhanced levels of satisfaction for both the endoscopist and the patient, without any impact on ventilation and safety. The use of bioimpedance monitoring of ventilation during colonoscopy is a suitable approach that may enhance the safety of procedural sedation.

Citations

Citations to this article as recorded by  
  • Comment on “Impact of opioid addition on procedural conditions during colonoscopy: a randomized trial comparing propofol-based sedation protocols”
    Ekrem Aslan
    Clinical Endoscopy.2026; 59(3): 481.     CrossRef
  • 6,584 View
  • 171 Download
  • 1 Web of Science
  • 1 Crossref
Close layer
Microbiological surveillance result of endoscopes after INTERCEPT Foam Spray: a quasi-experimental pilot study in Singapore
Caihong Wang, Rong Zhang, Ruhui Fan, Jiewen Low, Ruochen Du, Xueyun Ma, Congcong Cai
Clin Endosc 2024;57(6):821-831.   Published online November 4, 2024
DOI: https://doi.org/10.5946/ce.2024.030
Graphical AbstractGraphical Abstract AbstractAbstract PDFSupplementary Material
Background
/Aims: This study aimed to assess the impact of INTERCEPT Foam Spray (IFS) application on delayed endoscope reprocessing through microbiological surveillance culture (MSC).
Methods
A quasi-experimental, matched-comparison pilot study was conducted using gastrointestinal endoscopy. IFS was applied to the endoscopes after precleaning and before reprocessing the next day. An equal number of endoscopes, matched by endoscope type, were subjected to routine reprocessing. The MSC were subjected to high-level disinfection to detect any contamination. Data were analyzed using the chi-square test or Fisher exact test (categorical data) and Student t-test (continuous data).
Results
In total, 150 MSCs were collected from 42 endoscopes. Positive MSCs were observed in 4.0% (4/75) of the sprayed group and 1.3% (1/75) of the control group (95% confidence interval, 30.34–0.31; p>0.05), all of which were contributed by colonoscopes. Colonoscope were more prone to positive MSC (mean difference in percentage, p<0.05). Mean spraying hours were not associated with detected growth (11.7% vs. 13.6%; 95% confidence interval, 1.43 to –5.27; p>0.05), with environmental and skin flora being the primary contaminants.
Conclusions
IFS may be applied when delayed endoscope processing is necessary, but with caution when applied to colonoscopes. However, further research is warranted to verify the result.

Citations

Citations to this article as recorded by  
  • Genomic epidemiology of Salmonella Typhimurium and its monophasic variants in Southern China: A spatiotemporal and source attribution analysis
    Ningbo Liao, Shunxiong Lei, Chengwei Liu, Shengnan Tang, Silu Peng
    One Health.2026; 22: 101299.     CrossRef
  • Evaluation of endoscopic processing on the potential for Clostridiodes difficile transmission
    D. Ramkumar, M. Pezzone, A. Kinzler, M. Durst, H. Dixon, M. Yassin
    Infection Prevention in Practice.2026; 8(2): 100524.     CrossRef
  • Effect of a Modified Air-Gun Purging Method on Microbial Detection of Endoscope Drying Air: A Comparative Study
    Zhenfei Bao, Qian Yu, Wenjin Fan, Yubo Shi, Mengting Zhu, Weihong Wang
    Journal of Hospital Infection.2026;[Epub]     CrossRef
  • Efficacy of spray flushing in the reprocessing of flexible endoscopes
    Harendra Kumar, Arkadeep Dhali, Rick Maity, Jyotirmoy Biswas
    World Journal of Gastrointestinal Endoscopy.2025;[Epub]     CrossRef
  • Endoscope processing effectiveness: A reality check and call to action for infection preventionists and clinicians
    Cori L. Ofstead, Abigail G. Smart, Lydia L. Hurst, Larry A. Lamb
    American Journal of Infection Control.2025; 53(7): 785.     CrossRef
  • 7,007 View
  • 150 Download
  • 4 Web of Science
  • 5 Crossref
Close layer
Efficacy of a novel channel-cleaning ball brush for endoscope reprocessing: a randomized controlled trial
Kwang Hyun Chung, Jeong Don Chae, Wonho Choe, Hyo Young Lee, Il Hwan Oh, Byoung Kwan Son
Clin Endosc 2022;55(5):674-682.   Published online August 2, 2022
DOI: https://doi.org/10.5946/ce.2021.210
AbstractAbstract PDFSupplementary Material
Background
/Aims: Endoscopic channels are difficult to clean and can cause infection transmission. We examined the effectiveness of a newly developed channel-cleaning ball brush (BB), which is sucked into the endoscopic channel and scrapes and cleans the lumen as it passes through.
Methods
The upper and lower gastrointestinal endoscopes used for patient examinations were randomly selected as the conventional brush (CB) or BB group. After manual cleaning, the presence or absence of carbohydrates, proteins, adenosine triphosphate, and hemoglobin was assessed.
Results
Fifty-six and 58 endoscopes were cleaned with the CB and BB, respectively. Carbohydrate and protein were detected in one (1.8%) and two endoscopes (3.4%) in the CB and BB groups, respectively (p=1.000). Hemoglobin was observed in one (1.8%) and three endoscopes (5.2%) in the CB and BB groups, respectively (p=0.636). The adenosine triphosphate levels were 10.6±15.9 and 12.5±14.3 relative light units in the CB and BB groups, respectively (p=0.496). Twenty-seven (48.2%) and 19 (32.8%) endoscopes were positive for microbial cultures in the CB and BB groups, respectively (p=0.136).
Conclusions
The efficacy of BB was not significantly different from that of CB in the endoscopic channel-cleaning process.

Citations

Citations to this article as recorded by  
  • Effectiveness of Reprocessing Protocols for Reusable Endoscopes in Operating Rooms: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Yanxin Qu, Xiaonan Liu, Dening An, Haimeng Wei, Zhengjun Zhang, Shuai Tao
    Bratislava Medical Journal.2026; 127(6): 2114.     CrossRef
  • Manual brushing in endoscope reprocessing: how brush design impacts endoscope cleaning efficacy
    I. Beaugelin, L. Pineau
    Journal of Hospital Infection.2026; 174: 211.     CrossRef
  • Biomimetic Mustard Seed-Inspired Brush-Free Alternative for Effective Endoscope Channel Cleaning and Decontamination
    Suk-Dae Lim, Hyun Cho, Sun-Ho Choi, Hong-Gun Kim, Young-Soon Kim
    Biomimetics.2026; 11(8): 571.     CrossRef
  • An investigation into cleaning quality of suction-type metal lumen instruments: a cross-sectional study
    Yuqi Wu, Li Li
    Scientific Reports.2025;[Epub]     CrossRef
  • A prospective, quasi-experimental study on the efficacy of a novel double-headed endoscope cleaning brush for cleaning flexible endoscopes
    Rui Shen, Yaping Wu, Jiajun Lv, Qukai Liu, Weiyan Yao, Shu Chen, Dandan Liu, Huijun Xi, Yibo Zhang
    BMC Gastroenterology.2025;[Epub]     CrossRef
  • Comparison of brushing efficacy for gastroscopes using different brush types under simulated contamination conditions
    J.Y. Li, W.Q. Hu, C.Y. Zhou, Y.X. Ge, Q. Gu
    Journal of Hospital Infection.2025; 162: 160.     CrossRef
  • Simulated-use evaluation of rapid ChannelCheck™ cleaning test for optimal detection of organic residues in flexible endoscope channels
    K. Kulkarni, M. Gavette, M.J. Alfa
    Journal of Hospital Infection.2024; 152: 66.     CrossRef
  • 8,850 View
  • 230 Download
  • 7 Web of Science
  • 7 Crossref
Close layer
Special Review: Korean Society of Gastrointestinal Endoscopy “Accreditation of Qualified Endoscopy Unit” Guideline: Update 2019
Updates on the Sedation for Gastrointestinal Endoscopy
Jun Kyu Lee, Yoo Jin Lee, Jun Hyung Cho, Jong Pil Im, Chang-Hwan Park, Jae-Young Jang, Byung Ik Jang, the Quality Management Committee and the Disinfection Management/Conscious Sedation Committee of Korean Society of Gastrointestinal Endoscopy (KSGE)
Clin Endosc 2019;52(5):451-457.   Published online September 30, 2019
DOI: https://doi.org/10.5946/ce.2019.172
AbstractAbstract PDFSupplementary Material
Sedation, defined as the depressed level of consciousness, induced by drug administration, is widely used for gastrointestinal endoscopy to relieve a patient’s anxiety and discomfort. In addition, successful procedure is anticipated with control of unintended movements. Endoscopic sedation, however, cannot be free from the risk of serious adverse events, e.g., cardiopulmonary compromise. Therefore, principles on personnel, facility and equipment, as well as performance itself, should be followed to prevent unfavorable incidents. In this article, sedation guidelines for the Accreditation of Qualified Endoscopy Units, issued by the Korean Society of Gastrointestinal Endoscopy, are presented.

Citations

Citations to this article as recorded by  
  • Clinician-reported Gloucester Comfort Scale scores underestimate patient discomfort and pain during colonoscopy: insights from comparison with a patient-reported experience measure
    Querijn N. E. van Bokhorst, Charmayne V. Geerlings, Manon van der Vlugt, Karlijn J. Nass, Jos W. Borkent, Laura J. Neilson, Paul Fockens, Colin J. Rees, Evelien Dekker
    Endoscopy.2025; 57(06): 645.     CrossRef
  • Nurse-Administered Propofol Sedation Training Curricula and Propofol Administration in Digestive Endoscopy Procedures
    Andrea Minciullo, Lucia Filomeno
    Gastroenterology Nursing.2024; 47(1): 33.     CrossRef
  • Sedation reversal trends at outpatient ambulatory endoscopic center vs in-hospital ambulatory procedure center using a triage protocol
    Saqib Walayat, Peter Stadmeyer, Azfar Hameed, Minahil Sarfaraz, Paul Estrada, Mark Benson, Anurag Soni, Patrick Pfau, Paul Hayes, Brittney Kile, Toni Cruz, Deepak Gopal
    World Journal of Gastrointestinal Endoscopy.2024; 16(7): 413.     CrossRef
  • Propofol Alone versus Propofol in Combination with Midazolam for Sedative Endoscopy in Patients with Paradoxical Reactions to Midazolam
    Ji Hyung Nam, Dong Kee Jang, Jun Kyu Lee, Hyoun Woo Kang, Byung-Wook Kim, Byung Ik Jang
    Clinical Endoscopy.2022; 55(2): 234.     CrossRef
  • Endoscopist-Driven Sedation Practices in South Korea: Re-evaluation Considering the Nationwide Survey in 2019
    Seon-Young Park, Jun Kyu Lee, Chang-Hwan Park, Byung-Wook Kim, Chang Kyun Lee, Hong Jun Park, Byung Ik Jang, Dong Uk Kim, Jin Myung Park, Jae Min Lee, Young Sin Cho, Hyung Ku Chon, Seung Young Seo, Woo Hyun Paik
    Gut and Liver.2022; 16(6): 899.     CrossRef
  • Drugs used for sedation in gastrointestinal endoscopy
    Jun Kyu Lee
    Journal of the Korean Medical Association.2022; 65(11): 735.     CrossRef
  • Pain Intensity at Injection Site during Esophagogastroduodenoscopy Using Long- and Medium-Chain versus Long-Chain Triglyceride Propofol: A Randomized Controlled Double-Blind Study
    Joon Seop Lee, Eun Soo Kim, Kwang Bum Cho, Kyung Sik Park, Yoo Jin Lee, Ju Yup Lee
    Gut and Liver.2021; 15(4): 562.     CrossRef
  • A Nationwide Survey on the Facilities and Personnel for Endoscopic Sedation: Results from 50 Qualified Endoscopy Units of Teaching Hospitals Accredited by the Korean Society of Gastrointestinal Endoscopy (KSGE)
    Seon-Young Park, Jun Kyu Lee, Jung-Wook Kim, Tae Hee Lee, Chang-Hwan Park, Jae-Yong Jang, Byung-Wook Kim, Byung Ik Jang
    Clinical Endoscopy.2021; 54(6): 843.     CrossRef
  • Risk Factors for Prolonged Hospital Stay after Endoscopy
    Toshihiro Nishizawa, Shuntaro Yoshida, Osamu Toyoshima, Tatsuya Matsuno, Masataka Irokawa, Toru Arano, Hirotoshi Ebinuma, Hidekazu Suzuki, Takanori Kanai, Kazuhiko Koike
    Clinical Endoscopy.2021; 54(6): 851.     CrossRef
  • 12,787 View
  • 274 Download
  • 12 Web of Science
  • 9 Crossref
Close layer
Focused Review Series: Endoscopic Disinfection in the Era of MERS
Recent Update on Microbiological Monitoring of Gastrointestinal Endoscopes after High-Level Disinfection
Suk Pyo Shin, Won Hee Kim
Clin Endosc 2015;48(5):369-373.   Published online September 30, 2015
DOI: https://doi.org/10.5946/ce.2015.48.5.369
AbstractAbstract PDF

Endoscopy-related infections are important contributors to nosocomial infections. Endoscope reprocessing according to standard guidelines ensures high-level disinfection and prevents endoscopy-related infections. Microbiological surveillance may help in monitoring the effectiveness of gastrointestinal endoscope disinfection. The process involves microbial cultures and non-culture methods such as bioburden assays, adenosine triphosphate (ATP) bioluminescence, and quantitative polymerase chain reactions (PCRs). Surveillance culturing to monitor endoscopes after reprocessing has been recommended by a majority of organizations. Bioburden assays, ATP bioluminescence, and quantitative PCRs provide rapid and reliable measures. Each institution will have to try to establish its own surveillance guidelines.

Citations

Citations to this article as recorded by  
  • Bacterial bioluminescence for the real time and in situ monitoring of endoscope disinfection using plasma activated water
    Naomi Northage, Joshua A. C. Steven, Darren M. Reynolds, Malcolm J. Horsburgh, James L. Walsh, Robin M. S. Thorn, Pranita D. Tamma
    Antimicrobial Agents and Chemotherapy.2026;[Epub]     CrossRef
  • Analysis of positive surveillance cultures of flexible gastrointestinal endoscopes: a 6-year study in a tertiary medical centre in Taiwan
    S-H. Wang, M-Y. Wu, H-S. Hsu, M-H. Liang, C-S. Chung, C-H. Liao
    Journal of Hospital Infection.2026; 174: 203.     CrossRef
  • A PBMC-based assay detects residual pro-inflammatory response in endoscopes after high-level disinfection undetected by ATP bioluminescence: a pilot study.
    Troy Ejsmentewicz, Roxana Gonzalez-Stegmaier, Francisca Asis, Celia Podesta-Medina, Karen Saldivia, Franz Villarroel-Espíndola, Gerthy Rios-Rioseco
    Journal of Hospital Infection.2026;[Epub]     CrossRef
  • A comparative assessment of contamination rates in gastrointestinal endoscope reprocessing: sterilization versus high‐level disinfection
    Tanyaporn Chantarojanasiri, Rachanikorn Rungrueangmaitree, Siriporn Thongsri, Urasa Jampa‐ngern, Thawee Ratanachu‐Ek
    DEN Open.2025;[Epub]     CrossRef
  • A Comprehensive Review of Digestive Endoscopy-Associated Infections: Bacterial Pathogens, Host Susceptibility, and the Impact of Viral Hepatitis
    Deniz Günșahin, Vasile Șandru, Gabriel Constantinescu, Mădălina Ilie, Teodor Cabel, Ramona Ștefania Popescu, Bogdan Silviu Ungureanu, Victor Daniel Miron, Gheorghe G. Balan, Diana Cotigă, Bogdan Miutescu, Gülşen Özkaya Şahin, Oana Săndulescu
    Microorganisms.2025; 13(9): 2128.     CrossRef
  • Monthly endoscopy surveillance culture facilitates detection of breaches in the scope reprocessing procedure: 5‐year experience in an endoscopy center
    Shu‐Hui Chen, Theophile Liu, Huei‐Wen Lai, Hui‐Lan Chang, Hsu‐Heng Yen
    Advances in Digestive Medicine.2022; 9(2): 103.     CrossRef
  • Gastrointestinal Endoscopy-Associated Infections: Update on an Emerging Issue
    Anasua Deb, Abhilash Perisetti, Hemant Goyal, Mark M. Aloysius, Sonali Sachdeva, Dushyant Dahiya, Neil Sharma, Nirav Thosani
    Digestive Diseases and Sciences.2022; 67(5): 1718.     CrossRef
  • Microbiological Surveillance of Endoscopes in a Southern Italian Transplantation Hospital: A Retrospective Study from 2016 to 2019
    Valentina Marchese, Daniele Di Carlo, Gaetano Fazio, Santi Mauro Gioè, Angelo Luca, Rossella Alduino, Monica Rizzo, Fabio Tuzzolino, Francesco Monaco, Pier Giulio Conaldi, Bruno Douradinha, Giuseppina Di Martino
    International Journal of Environmental Research and Public Health.2021; 18(6): 3057.     CrossRef
  • The application of plan, do, check, act (PDCA) quality management in reducing nosocomial infections in endoscopy rooms: It does work
    Xiaoming Kong, Xiaolu Zhu, Yidan Zhang, Jie Wu
    International Journal of Clinical Practice.2021;[Epub]     CrossRef
  • Does the Reprocessing of Endoscopes Have to Take Place Immediately after Pre-Cleaning? A First Evaluation
    Vanessa M Eichel, Jonas M Jabs, Samy Unser, Nico T Mutters, Martin Scherrer
    Clinical Endoscopy.2021; 54(4): 526.     CrossRef
  • Turbulent fluid flow is a novel closed-system sample extraction method for flexible endoscope channels of various inner diameters
    Seo Yean Sohn, Michelle J. Alfa, Richard Lai, Yacoob Tabani, Mohamed E. Labib
    Journal of Microbiological Methods.2020; 168: 105782.     CrossRef
  • Duodenoscope as a Vector for Transmission
    Jennifer T. Higa, Andrew S. Ross
    Gastrointestinal Endoscopy Clinics of North America.2020; 30(4): 653.     CrossRef
  • A Prospective, Randomized Comparison of Duodenoscope Reprocessing Surveillance Methods
    Travis J. De Wolfe, Nasia Safdar, Megan Meller, John Marx, Patrick R. Pfau, Eric M. Nelsen, Mark E. Benson, Anurag Soni, Mark Reichelderfer, Megan Duster, Deepak V. Gopal
    Canadian Journal of Gastroenterology and Hepatology.2019; 2019: 1.     CrossRef
  • Comparative Study of Microbiological Monitoring Results from Three Types of Sampling Methods after Gastrointestinal Endoscope Reprocessing
    Su Ma, Lili Feng, Ziyi Jiang, Xian Gao, Xisha Long, Shaonan Zhuang, Wenxia Ding, Taiyao Chen, Zhaoshen Li, Lingjuan Zhang, Huijun Xi, Hongzhi Zhang
    BioMed Research International.2019; 2019: 1.     CrossRef
  • Métodos microbiológicos para la monitorización de la limpieza, desinfección y esterilización de dispositivos médicos
    Rosa María Blázquez-Garrido, Eva Cuchí-Burgos, Carmen Martín-Salas, Patricia Ruiz-Garbajosa
    Enfermedades Infecciosas y Microbiología Clínica.2018; 36(10): 657.     CrossRef
  • The validity of adenosine triphosphate measurement in detecting endoscope contamination
    C.E. McCafferty, D. Abi-Hanna, M.J. Aghajani, G.T. Micali, I. Lockart, K. Vickery, I.B. Gosbell, S.O. Jensen
    Journal of Hospital Infection.2018; 100(3): e142.     CrossRef
  • Microbiological monitoring of medical devices after cleaning, disinfection and sterilisation
    Rosa María Blázquez-Garrido, Eva Cuchí-Burgos, Carmen Martín-Salas, Patricia Ruiz-Garbajosa
    Enfermedades infecciosas y microbiologia clinica (English ed.).2018; 36(10): 657.     CrossRef
  • Association Between Storage Interval and Contamination of Reprocessed Flexible Endoscopes in a Pediatric Gastrointestinal Procedural Unit
    Patricia Scanlon, Kathleen Flaherty, Erik A. Reilly, Ellen G. Barth, Gail Potter-Bynoe, Jeff Cardini, Ann Marie Riley, Alexander J. McAdam, Thomas J. Sandora
    Infection Control & Hospital Epidemiology.2017; 38(2): 131.     CrossRef
  • Surveillance of Endoscopes: Comparison of Different Sampling Techniques
    Lien Cattoir, Thomas Vanzieleghem, Lisa Florin, Tania Helleputte, Martine De Vos, Bruno Verhasselt, Jerina Boelens, Isabel Leroux-Roels
    Infection Control & Hospital Epidemiology.2017; 38(9): 1062.     CrossRef
  • Education and Training Guidelines for the Board of the Korean Society of Gastrointestinal Endoscopy
    Hee Seok Moon, Eun Kwang Choi, Ji Hyun Seo, Jeong Seop Moon, Ho June Song, Kyoung Oh Kim, Jong Jin Hyun, Sung Kwan Shin, Beom Jae Lee, Sang Heon Lee
    Clinical Endoscopy.2017; 50(4): 345.     CrossRef
  • Sterile Reverse Osmosis Water Combined with Friction Are Optimal for Channel and Lever Cavity Sample Collection of Flexible Duodenoscopes
    Michelle J. Alfa, Harminder Singh, Zoann Nugent, Donald Duerksen, Gale Schultz, Carol Reidy, Patricia DeGagne, Nancy Olson
    Frontiers in Medicine.2017;[Epub]     CrossRef
  • The Assessment and Improvement of the Steps in the Endoscope-Reprocessing: A Hospital Report
    Habip Gedik
    Journal of Bacteriology & Mycology: Open Access.2017;[Epub]     CrossRef
  • Duodenoscope-Associated Bacterial Infections: A Review and Update
    Jennifer T. Higa, Michael Gluck, Andrew S. Ross
    Current Treatment Options in Gastroenterology.2016; 14(2): 185.     CrossRef
  • 16,127 View
  • 270 Download
  • 21 Web of Science
  • 23 Crossref
Close layer
Case Report
Body Position Adjustment May Facilitate Capsule Endoscopic Real-Time Examination in Patients with a Large Amount of Food Retention in the Stomach
Ju-Hua Gou, Bing-Qiang Zhang
Clin Endosc 2014;47(3):266-269.   Published online May 31, 2014
DOI: https://doi.org/10.5946/ce.2014.47.3.266
AbstractAbstract PDFSupplementary Material

A patient with acute obscure gastrointestinal bleeding was found to have a large amount of food retention in the stomach after fasting for >12 hours. We tried to adjust the patient's body position to facilitate capsule endoscopic examination. The patient laid on the bed on his right side, which is the position required for a normal procedure, and then his hip was raised while his upper body was lowered gradually until the pylorus appeared at the center of the screen of the real-time monitor. It took 15 minutes of body position adjustment to make the pylorus appear at the center of the monitor and another 5 minutes for the capsule endoscope to enter the duodenum. The lesion was ultimately found at the terminal small intestine.

Citations

Citations to this article as recorded by  
  • Development and Testing of a Magnetically Actuated Capsule Endoscopy for Obesity Treatment
    Thanh Nho Do, Tian En Timothy Seah, Ho Khek Yu, Soo Jay Phee, Masaru Katoh
    PLOS ONE.2016; 11(1): e0148035.     CrossRef
  • 8,260 View
  • 51 Download
  • 1 Web of Science
  • 1 Crossref
Close layer
Focused Review Series: Endoscopic Sedation Revisited: Principles and Practice
Endoscopic Sedation: Risk Assessment and Monitoring
Young Chul Yoo
Clin Endosc 2014;47(2):151-154.   Published online March 31, 2014
DOI: https://doi.org/10.5946/ce.2014.47.2.151
AbstractAbstract PDF

Sedation for endoscopic procedures is done to increase patient comfort and endoscopic performance. Drugs used for sedation suppress respiratory and cardiovascular function, and while the degree of suppression may vary, it may be fatal in certain patients. The aim of this article is to provide an overview and brief summary of presedation risk assessment and monitoring during and after sedation in order to maintain patient safety.

Citations

Citations to this article as recorded by  
  • Intravenous lidocaine with propofol‐based sedation for colonoscopy: a systematic review and meta‐analysis with trial sequential analysis
    Eduardo C. Barbosa, Júlia M. Aguirre, Paulo F. E. Bertoldi, Paula Santo, Stefano Baraldo, Angélica L. Nau, Gilmara C. Meine
    Anaesthesia.2025; 80(6): 694.     CrossRef
  • A soft robotic “Add-on” for colonoscopy: increasing safety and comfort through force monitoring
    Viola Del Bono, Max McCandless, Arincheyan Gerald, Emma Capaldi, Johann Pang, Casper Muter, Mark Baldiswieler, Hiroyuki Aihara, Sheila Russo
    npj Robotics.2025;[Epub]     CrossRef
  • Endoscopy of Low BMI Patients Compared to Normal BMI Patients: A Study From the Asser Region, Saudi Arabia
    Yahia Al-Hagawi, Nasser I Alqahtani, Saeed Nasser Alsharif, Rafaat Chakik, Dawlah Hadi Asiri, Salihah Y Al mani, Azizah Badawi, Haneen Ahmad Al-assiri, Hana Saeed Al Malih, Hend Alamri, Amjad Saad AlAli, Aisha A Ali Alqhtani, Asiah A Al-BinAbdullah, Moha
    Cureus.2024;[Epub]     CrossRef
  • Ciprofol versus propofol for adult sedation in gastrointestinal endoscopic procedures: a systematic review and meta-analysis
    Guilherme H. ORTEGAL, Eduardo C. BARBOSA, Pedro C. FARIA, João V. COUTO, Guilherme C. SILVA, Márcio H. SOUZA, Lucas N. FERREIRA, Vitor R. MORAES, Maria C. CAMPOS, Luiza A. CAMPOS
    Minerva Anestesiologica.2024;[Epub]     CrossRef
  • Colonoscopy: an evidence-based approach
    Lucy Kelly
    Nursing Standard.2022; 37(4): 77.     CrossRef
  • A Delayed Fatal Septic Cerebral Infarction after Endoscopic Retrograde Cholangiopancreatography
    Sung Hak Lee, Pyung Kang Park, Kyoung Young Lee, Woo-Cho Chung, Seung Goun Hong
    Soonchunhyang Medical Science.2015; 21(2): 121.     CrossRef
  • 12,709 View
  • 121 Download
  • 3 Web of Science
  • 6 Crossref
Close layer
경미한 미란성 식도염에서 식도 운동 및 위산 역류의 양상 ( Patterns of Gastroesophageal Reflux and Esophageal Motility in Patients with Mild Reflux Esophagitis )
Korean J Gastrointest Endosc 1999;19(5):693-699.   Published online November 30, 1998
AbstractAbstract PDF
Background
/Aims: The major complications of reflux esophagitis are stricture formation and Barrett's esophagus. In Korea, the incidence of these complications is low and most patients with reflux esophagitis undergo a mild clinical course. The purpose of this study was to investigate patterns of acid reflux and esophageal motility in mild reflux esophagitis in Korea. Methods: Using conventional manometry and 24-hour ambulatory pH monitoring, we were investigated esophageal motility and patterns of gastroesophageal reflux in 41 patients with reflux esophagitis Savary-Miller (S-M) Ib using on endoscopy. The total supine, and upright reflux periods, as well as frequency and duration of reflux episodes were determined from the 24-hour pH monitoring record using standard software. Pathologic reflux was defined when the percentage of the total time with pH less than 4 (acid exposure time) exceeded 4%. Results: Pathologic reflux was observed in 17 patients (41.5%), who were categorized into upright refluxers (70.6%), supine refluxers (11.8%), and combined refluxers (17.6%). Patients with reflux esophagitis did not differ in lower esophageal sphincter pressure from the normal subjects. There were two patients (4.9%) with a lower esophageal pressure ≤ 10 mmHg and four patients (9.8%) with hiatal hernia. Failed peristalsis was seen in 4 patients (9.8%). Conclusions: A high proportion of upright reflux and low incidence of esophageal peristaltic dysfunction may contribute to the low incidence of stricture formation and Barrett's esophagus in patients with mild reflux esophagitis in Korea. (Korean J Gastrointest Endosc 19: 693∼699, 1999)
  • 2,665 View
  • 7 Download
Close layer

Clin Endosc : Clinical Endoscopy Twitter Facebook
Close layer
TOP