Korean J Gastrointest Endosc > Volume 19(2); 1999 > Article
Korean Journal of Gastrointestinal Endoscopy 1999;19(2): 235-241.
악성 폐쇄성 황달환자에서 코일형 (EndocoilTM) 금속배액관과 플라스틱 배액관의 비교 (Randomised Trial of Coil (EndocoilTM) Stent Versus Plastic Stent in Malignant Biliary Tract Obstruction)
이돈행, 송시영, 정재복, 문영명, 강진경, 박인서 (Don Haeng Lee, Si Young Song, Jae Bock Chung, Young Myung Moon, Jin Kyung Kang and In Suh Park)
Abstract

Background/Aims:
Endoscopic stent placement has become accepted palliative therapy for malignant biliary tract obstruction (MBTO). The main problem of plastic stent are the clogging or migration. The new self expandable super-elastic metallic coil stent (Endo-coilTM, Instent Inc.) is claimed to allow large lumen and prolong biliary-stent patency. In a prospective randomised trial, we compared the efficacy and frequency of stent dysfunction of EndocoilTMand plastic stent (PercuflexR, Microvasive Co.).
Method:
Bet-ween Aug. 1994 and Mar. 1995, we assigned 29 patients (21 males and 8 females, mean age 63 years) with unresectable MBTO due to cancer of bile duct (17), pancreas (6) periampullary (3), gallbladder (2) and perichoedochal LN (1). Thirteen of patients under-went EndocoilTMstents (24 Fr) and other 16 patients underwent plastic stents (12 Fr) insertion via transpapillary route. Successful insertion of stents was attained all cases and no serious complication occured.
Results:
All patients with EndocoilTM stents and 11 (68%) patients with plastic stents were relieved completely from jaundice (T. bilirubon <3.0 mg/dl). There was no differences in decreasement of bilirubin between two groups after 7 days and 30 days after stents insertion. Median patency of the stents was significantly prolonged in patients with EndocoilTM stents compared with those with plastic stents(205 days vs 92 days). The stent dysfunction was noted 2 cases (15%) in EndocoilTM due to tumor ingrowth. In contrast, stent dysfunction was occured in 10 cases (62%) of plastic stents due to clogging (7 cases) and migration (3 cases). The patients' overall median survival was not different significantly between two groups (EndocoilTM250 days vs plastic 196 days).
Conclusions:
Both ndocoilTMand plastic stents offer effective bile drainage in MBTO. However EndocoilTM stents may be more effective for providing longer periods of drainage due to lower frequency of stent dysfuction than plastic stents. (Korean J Gastrointest Endosc 19: 235 ∼241, 1999)
Key Words: EndocoilTMstent, Plastic stent, Comparative study, Malignant biliary tract obstruction (MBTO)
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
1,389
View
6
Download
Related article
Editorial Office
Korean Society of Gastrointestinal Endoscopy
#817, 156 Yanghwa-ro (LG Palace, Donggyo-dong), Mapo-gu, Seoul, 04050, Korea
TEL: +82-2-335-1552   FAX: +82-2-335-2690    E-mail: CE@gie.or.kr
Copyright © Korean Society of Gastrointestinal Endoscopy.                 Developed in M2PI
Close layer