Abstract
- As endoscopic therapy has progressed, various endoscopic closure techniques have been developed to prevent adverse events and to facilitate complex therapeutic procedures. The development of closure techniques began in the 1970s with the introduction of clipping for mucosal defects after gastric polypectomy. Currently, these techniques are applied primarily to prevent post-procedural bleeding from mucosal defects resulting from endoscopic submucosal dissection; to repair iatrogenic perforations involving full-thickness defects; and to complete endoscopic full-thickness resection. They can be categorized into clipping, tissue apposition, suturing, and stapling, each with distinct advantages and disadvantages. Therefore, familiarity with each method and the ability to select the most appropriate technique for a given situation are essential.
-
Keywords: Endoscopic closure; Endoscopic full-thickness resection; Endoscopic submucosal dissection; Endoscopic suturing; Postoperative bleeding
INTRODUCTION
Endoscopic closure methods have evolved alongside the development of endoscopic treatment techniques. Initially, endoscopic hemostasis focused on gastrointestinal bleeding caused by common conditions, such as peptic ulcers and esophageal varices, before diversifying into various hemostatic methods. Among these, clipping of bleeding vessels in gastric ulcer hemorrhage was widely adopted by surgeons—the primary practitioners of endoscopy at that time—as a mechanical means of achieving hemostasis analogous to vascular ligation using sutures. Since the clinical introduction of endoscopic gastric polypectomy in 1968, various techniques for tissue resection and retrieval have been developed for the treatment of gastrointestinal lesions. These techniques progressed to endoscopic mucosal resection (EMR) in 1980 and subsequently to endoscopic submucosal dissection (ESD), thereby considerably expanding their indications. The major complications of post-procedural bleeding and perforation associated with ESD have become increasingly important, particularly because mucosal defects enlarge as the target lesion increases in size. As the number of elderly patients receiving antithrombotic agents has steadily increased in recent years, post-procedural bleeding—which is technically difficult to manage—and delayed perforation, although rare, can be severe. These complications therefore remain challenging to treat, even a quarter of a century after the introduction of ESD.
Nevertheless, there is no doubt that endoscopic treatment is less invasive than surgery. Therefore, its indications have expanded beyond the excision of epithelial tumors to include subepithelial tumors (SETs) and other diseases that can be cured by local resection. If the target lesion can be removed transorally, endoscopic full-thickness resection (EFTR) provides a less invasive curative alternative to surgery by allowing SETs to be resected en bloc, similar to local surgical resection. However, a technique is required that allows not only the intentional creation of a perforation for resection of SETs located deep within the digestive tract wall, but also reliable closure of the full-thickness defect from the luminal side. Although endoscopic closure is often difficult in cases of accidental gastrointestinal perforation or fistula caused by postoperative anastomotic leakage, EFTR cannot be considered complete until the resection site has been closed. Therefore, a safe, reliable, and effective full-layer closure method is necessary to further refine this technique.
Endoscopic closure aims to prevent post-ESD bleeding and delayed perforation and is indispensable for EFTR. Various closure methods have been developed; however, each technique has advantages and disadvantages with respect to technical difficulty, durability of closure, device availability, and procedural cost. Moreover, the difficulty of each procedure depends on the target lesion, its location, and the size of the defect. In particular, mucosal defects resulting from ESD differ substantially from full-thickness defects resulting from EFTR.
The present discussion first reviews various endoscopic closure techniques and categorizes them from the authors’ point of view as well as according to the target lesion—such as mucosal and full-thickness defects—and then provides a brief description of each technique.
DEFINITION AND CATEGORIES OF ENDOSCOPIC CLOSURE
Endoscopic closure is defined as the closure of a gastrointestinal defect using a flexible endoscope. Several approaches exist, including clipping, tissue apposition, suturing, and stapling (Table 1). These approaches can be compared according to various parameters, such as ease of performance, speed, cost, simplicity, reversibility, and durability. It is essential to understand the characteristics of each technique—including its advantages and disadvantages—before selecting the method most appropriate for a given patient, the hospital’s resources, and the endoscopist’s level of experience.
TARGETS OF ENDOSCOPIC CLOSURE
Endoscopic closure can be divided into mucosal closure and full-layer closure according to the target lesion. The former is primarily performed for mucosal defects resulting from EMR or ESD and aims to prevent post-procedural bleeding and delayed perforation. The latter is performed for transluminal fistulae, including intraoperative perforations occurring as complications of endoscopic treatment, postoperative anastomotic leakage, and full-thickness defects resulting from EFTR, and it serves as a troubleshooting measure for adverse events or as the final step in endoscopic treatment.
In mucosal defects, a clear visual field can be readily secured because intraluminal pressure is controlled by the operator. Furthermore, the target tissue can be manipulated through insufflation and deflation, allowing the procedure to be completed using intraluminal endoscopy. However, the underlying muscular layer exerts force in the direction opposite to that of mucosal closure, making sustained closure difficult to maintain. Mucosal defects are rarely closed intraoperatively; therefore, limited surgical evidence can be extrapolated to endoscopic practice, and the incomplete understanding of the mechanisms underlying dehiscence hinders procedural development. Dehiscence is thought to be influenced by mucosal thickness, peristaltic forces, and the closure method. In general, maintaining closure in the stomach is considered more difficult than in the colon or duodenum.
The primary obstacle to closing a full-thickness defect is the difficulty of endoscopic manipulation when communication occurs between the lumen and the extraluminal space. Although a certain distance between the target and lens is required to secure an adequate working space, opening the gastrointestinal tract into the extraluminal space leads to luminal collapse and significantly impairs endoscopic maneuverability. Conversely, certain anatomical sites—such as the lesser curvature of the gastric body and the lower rectum—are less susceptible to luminal collapse even after full-thickness resection. The ability to predict the technical difficulty of full-thickness resection preoperatively, based on the lesion site, allows selection of the most appropriate closure method for each case. In contrast to mucosal defects, fewer factors interfere with maintenance of closure in full-thickness defects, including the absence of opposing muscular forces. Therefore, the risk of dehiscence remains low, provided that endoscopic closure is sufficiently secure. Unlike surgical resection, EFTR minimizes disruption of feeding arteries surrounding the lesion, thereby preserving blood flow to the defect. This preservation is thought to promote healing and reduce the risk of anastomotic leakage.
CLIPPING
Simple clipping uses a through-the-scope clip originally developed for hemostasis to approximate mucosal edges and cover the defect. It was proposed as an alternative to directly grasping exposed vessels at the polypectomy site. In 1975, Hayashi et al.1 introduced a method using clips with a maximum opening diameter of 15 mm to grasp vessels while simultaneously approximating the surrounding mucosa, in contrast to the direct approach that employs small hemostatic clips. This method is considered the prototype of the current mucosal closure technique using clips alone and has since been widely applied for relatively small mucosal defects, such as those resulting from EMR.
Clips are broadly categorized into two types: the through-the-scope type and the over-the-scope type, which is mounted on the tip of the endoscope. The fundamental technique consists of simple clipping with a through-the-scope clip, in which the clip arms are positioned against opposing wound edges before deployment. This method is simple and inexpensive; however, the grasping force and durability of closure are relatively limited, particularly in the stomach.2 For large defects resulting from colonic or duodenal ESD, closure along the short axis is technically feasible. The hold-and-drag technique is also effective. Using a reopenable clip, the mucosal margin is grasped and pulled toward the opposite side; the clip is then partially reopened to grasp the opposing mucosal margin before final closure.3 In the mucosal incision method,4 small incisions are created at several points along the mucosal margin to anchor the clip arms. In the clip-with-line method,5 a clip attached to a thread is placed on the distal mucosal margin, and the mucosal edges are approximated by pulling the thread proximally before clip deployment. By contrast, the over-the-scope clip (OTSC)6 provides strong tissue retention and can capture deeper layers; however, it is more expensive than standard clips, and retrieval of misplaced clips is difficult.
In 2011, a Chinese study of 26 cases involving EFTR described the use of through-the-scope type clips for mucosal closure without adverse events.7 Because the edges of full-thickness defects tend to evert, closure by grasping both edges with a clip is considered technically challenging. However, in areas where luminal collapse can be avoided, closure may be performed in a manner similar to that used for mucosal defects. Nevertheless, concerns regarding the durability of closure remain. Ohki et al.8 reported that approximation of multiple tissue layers, including the mucosal and muscular layers, is feasible by firmly retracting the defect edges outward with grasping forceps to linearize the circular defect margin. The OTSC provides strong tissue capture during closure of full-thickness defects and is considered highly reliable.9 Specialized double-opening grasping forceps or anchor forceps can be used to grasp tissue, including the muscular layer, to facilitate secure full-thickness closure. During the procedure, care must be taken to avoid entrapment of surrounding extraluminal organs. Although the ability of these forceps to firmly grasp tissue and maintain closure is advantageous for clipping, their limitations include the inability to close defects larger than approximately 1 cm per clip, high cost, and the potential for residual gaps between clips. Consequently, their use in routine clinical practice depends on the resources available at the treating facility.
TISSUE APPOSITION
Since the late 2000s, as ESD has become more widespread and the treatment of large mucosal defects—often difficult to manage with simple clipping alone—has increased, various clip-based closure methods have been evaluated in clinical practice. These methods are categorized as tissue apposition techniques and include the retention snare-and-clip method,10 which involves placing a retention snare at the mucosal margin using a clip and subsequently tightening it to approximate the mucosa; the 8-ring method11 and loop-clip method,12 which use a figure-of-eight loop or a small loop to approximate both sides of the mucosa; and the endoscopic ligation with O-ring closure method,13 in which bilateral clips are placed and cinched with an O-ring. In recent years, additional tissue apposition methods have been introduced, including Loop 9,14 which externally tightens a surgical suture deployed as a loop to close a defect in a purse-string fashion, and techniques using existing devices, such as the reopenable clip-over-the-line method (ROLM)15 and Loop 11,16 which are modifications of the clip-with-line method. Additionally, the X-Tack system (Boston Scientific),17 which involves implantation of screw-type tacks connected by a suture around a defect to enable suture cinching, can be used with any endoscope equipped with a working channel diameter of 2.8 mm or greater and is considered highly versatile.
In these techniques, the mucosal margins at both ends are grasped with clips. Therefore, the degree of slack in the suture or loop used to cinch the clips together determines the risk of dehiscence. To prevent dehiscence, efforts have been made to reduce dead space by incorporating the muscular layer at the center of the defect.18 This approach has been reported to be effective in maintaining closure of large mucosal defects.
These tissue apposition techniques have also been applied to closure of full-thickness defects. The retention snare-and-clip method,19 Loop 11,20 and ROLM21 appear to be relatively accessible approaches, partly because of device availability. The X-Tack system may also be useful in countries where it is available.22 However, mucosal closure alone for full-thickness defects remains challenging because of the risk of dehiscence. Consequently, secure full-layer clipping is recommended even when these tissue apposition techniques are used.
SUTURING
Endoscopic suturing is conceptually most similar to surgical closure and is generally considered highly acceptable. The procedure involves endoscopic closure of a defect using a suture needle and thread. Endoscopic suturing devices originated from the development of natural orifice transluminal endoscopic surgery (NOTES), which was designed to perform various endoscopic procedures extraluminally using a flexible endoscope inserted through intentionally created orifices.
The OverStitch system (Boston Scientific) is one of the few suturing devices currently in clinical use among the many that were evaluated in preclinical trials. The device features a handle mechanism that allows a curved needle mounted on the endoscope tip to swing transversely across the endoscopic field of view and penetrate tissue. The defect is closed by advancing the anchor and cinching the suture after placement of several consecutive stitches. The procedure is completed by cutting the excess suture with endoscopic scissors. Because of its technical complexity, thorough understanding of the procedure is required for proper execution. Although this technique can provide highly reliable defect closure, its high cost and lack of regulatory approval in Japan present significant barriers to clinical application.
OverStitch was initially used to close full-thickness defects, as NOTES was developed for extraluminal endoscopic treatment, and closure of mucosal defects was considered a secondary application of this technology.23 Furthermore, the device was developed in the United States, where ESD had not yet been widely established as a standard treatment at that time. Because OverStitch remains unavailable in Japan, there is currently limited evidence regarding its efficacy in closing mucosal defects.
Endoscopic hand suturing (EHS), a technique developed in Japan, combines the fundamental surgical technique of hand suturing with endoscopic guidance.24 Using SutuArt (Olympus), a dedicated flexible needle holder that enables continuous suturing with a barbed suture for closure of mucosal defects, EHS theoretically provides closure reliability comparable to that of conventional surgical suturing. The device can also be applied flexibly in various clinical scenarios.
Zeo-Suture M (Zeon Medical), another promising suturing device that penetrates tissue using a mechanism similar to that of a sewing machine, was developed in Japan and is now employed for multiple purposes, including closure of mucosal defects resulting from ESD.25
Previous studies have reported the use of OverStitch,26 Zeo-Suture M,27 and SutuArt28 for full-thickness wound closure. The first two devices primarily achieve closure through full-thickness single-layer suturing. In contrast, EHS using SutuArt permits a broader range of closure techniques in addition to full-thickness single-layer suturing, including mucosal single-layer suturing, muscular layer suturing combined with mucosal clipping, and double-layer suturing (Fig. 1). Nonetheless, all of these techniques are technically challenging in cases of luminal collapse. The first two procedures are easier to perform when the patient is positioned in the frontal orientation, which is most suitable for cases of complete luminal collapse caused by intentional perforation during EFTR. EHS is easier to perform when the patient is positioned horizontally, provided that the lumen offers a sufficient endoscopic field of view to allow adequate manipulation.
STAPLING
Various types of staplers, such as linear and circular staplers, have long been used in standard surgical procedures. Multiple prototypes specifically developed for endoscopic closure have been evaluated in animal studies29,30; however, their clinical application remains limited, and they are generally not indicated for cases requiring EFTR.
INDICATIONS AND SELECTION
Among the above-mentioned closure techniques, the currently available major methods for mucosal and full-thickness defects are illustrated in Figure 2. In clipping techniques, the OTSC can be applied to grasp the full layer, which may provide more reliable maintenance of closure. The ROLM is also expected to achieve full-thickness apposition. OverStitch contributes to single-layer full-thickness closure, whereas EHS offers greater flexibility for full-thickness defects by allowing selection of either single- or double-layer closure according to the clinical situation.
At present, determining the optimal technique for each type of defect is challenging because of the lack of sufficient clinical evidence directly comparing closure methods. Nevertheless, the authors present their personal perspectives on clinical indications and technique selection in Table 2 for the stomach and rectum and in Table 3 for the duodenum and colon, respectively, to provide readers with a reference framework for developing their own indications.
CONCLUSIONS
Endoscopic closure has evolved in parallel with the expanding indications for flexible endoscopy as a minimally invasive therapeutic modality aimed at preventing complications of endoscopic procedures and managing gastrointestinal perforations and fistulas. Endoscopic devices designed for defect closure—some of which remain in the preclinical trial phase—are being developed worldwide, and competition among developers is intense. Achieving an ideal closure method or device that is safe, simple, inexpensive, highly effective, and versatile requires overcoming numerous challenges. At present, endoscopists should aim to understand existing closure techniques in order to select the method most appropriate for a specific clinical situation. Understanding the range of techniques and the background of their development may facilitate this decision-making process. The authors hope that this article will assist readers in this regard.
Conflicts of Interest
Osamu Goto has received honoraria for lectures and training in endoscopic hand suturing from Olympus Co., Ltd. The other author has no potential conflicts of interest.
Funding
None.
Author Contributions
Conceptualization: OG; Writing–original draft: OG; Writing–review & editing: EK.
Fig. 1.Endoscopic hand suturing for full-thickness defects. (A) A submucosal tumor located on the lesser curvature of the gastric body is visible. (B) Full-thickness resection was performed. (C) The full-thickness defect resulting from tumor excision is shown. (D) The muscular layer was sutured using the endoscopic hand suturing technique. (E) Completed muscular layer suturing. (F) Subsequent mucosal layer suturing was performed in a manner similar to that used for muscular layer suturing. (G) The full-thickness defect was completely closed by double-layer suturing. (H) The gastrointestinal stromal tumor was curatively resected.
Fig. 2.Schematic representation of endoscopic closure techniques. (A) Clipping techniques are represented by simple closure using standard hemostatic clips and the over-the-scope clip. (B) Major tissue apposition techniques include the retention snare, reopenable clips with an eyelet, and dedicated tacks. (C) Currently available endoscopic suturing devices include the OverStitch and SutuArt systems, which enable endoscopic hand suturing. M, mucosa; MP, muscularis propria; OTSC, over-the-scope clip; ROLM, reopenable clip-over-the-line method; EHS, endoscopic hand suturing.
Table 1.Variety of endoscopic closure techniques
|
Procedure |
Category |
Method |
|
|
Endoscopic closure |
Clipping |
Through-the-scope clip |
|
|
|
Over-the-scope clip |
|
|
Tissue apposition |
Retention snare-and-clip method |
|
|
|
8-Ring method |
|
|
|
Loop-clip method |
|
|
|
Endoscopic ligation with O-ring closure |
|
|
|
Loop 9 |
|
|
|
Reopenable clip-over-the line method |
|
|
|
Loop 11 |
|
|
|
X-Tack |
|
|
Suturing |
OverStitch |
|
|
|
Zeo-Suture |
|
|
|
Endoscopic hand suturing |
|
|
Stapling |
GERDX |
|
|
|
SurgASSIST |
|
Table 2.Indications and selection of endoscopic closure techniques (stomach and rectum)
|
Category |
Method |
Mucosal defect |
Full-thickness defect |
|
|
Small |
Large |
Small |
Large |
|
|
Clipping |
Through-the-scope clip |
Optimal |
Discouraged |
Appropriate |
Discouraged |
|
|
OTSC |
Appropriate |
Inappropriate |
Optimal |
Inappropriate |
|
|
Tissue apposition |
Retention snare-and-clip method |
Inappropriate |
Fair |
Inappropriate |
Inappropriate |
|
|
ROLM |
Inappropriate |
Appropriate |
Inappropriate |
Appropriate |
|
|
X-Tack |
Inappropriate |
Fair |
Inappropriate |
Inappropriate |
|
|
Suturing |
OverStitch |
Inappropriate |
Appropriate |
Appropriate |
Optimal |
|
|
EHS |
Inappropriate |
Optimal |
Appropriate |
Appropriate |
|
Table 3.Indications and selection of endoscopic closure techniques (duodenum and colon)
|
Category |
Method |
Mucosal defect |
Full-thickness defect |
|
Small |
Large |
Small |
Large |
|
Clipping |
Through-the-scope clip |
Optimal |
Fair |
Appropriate |
Discouraged |
|
OTSC |
Appropriate |
Inappropriate |
Optimal |
Inappropriate |
|
Tissue apposition |
Retention snare-and-clip method |
Fair |
Appropriate |
Inappropriate |
Fair |
|
ROLM |
Fair |
Optimal |
Inappropriate |
Appropriate |
|
X-Tack |
Fair |
Appropriate |
Inappropriate |
Fair |
|
Suturing |
OverStitch |
Inappropriate |
Fair |
Fair |
Appropriate |
|
EHS |
Inappropriate |
Appropriate |
Fair |
Inappropriate |
REFERENCES
- 1. Hayashi T, Yonezawa M, Kuwahara T, et al. The study on stanch clips for the treatment by endoscopy. Gastroenterol Endosc 1975;17:92–101.Article
- 2. Choi KD, Jung HY, Lee GH, et al. Application of metal hemoclips for closure of endoscopic mucosal resection-induced ulcers of the stomach to prevent delayed bleeding. Surg Endosc 2008;22:1882–1886.ArticlePubMedPDF
- 3. Akimoto T, Goto O, Sasaki M, et al. "Hold-and-drag" closure technique using repositionable clips for large mucosal defects after colonic endoscopic submucosal dissection. Endosc Int Open 2016;4:E1068–E1072.ArticlePubMedPMC
- 4. Otake Y, Saito Y, Sakamoto T, et al. New closure technique for large mucosal defects after endoscopic submucosal dissection of colorectal tumors (with video). Gastrointest Endosc 2012;75:663–667.ArticlePubMed
- 5. Yahagi N, Nishizawa T, Akimoto T, et al. New endoscopic suturing method: string clip suturing method. Gastrointest Endosc 2016;84:1064–1065.ArticlePubMed
- 6. Maekawa S, Nomura R, Murase T, et al. Complete closure of artificial gastric ulcer after endoscopic submucosal dissection by combined use of a single over-the-scope clip and through-the-scope clips (with videos). Surg Endosc 2015;29:500–504.ArticlePubMedPMCPDF
- 7. Zhou PH, Yao LQ, Qin XY, et al. Endoscopic full-thickness resection without laparoscopic assistance for gastric submucosal tumors originated from the muscularis propria. Surg Endosc 2011;25:2926–2931.ArticlePubMedPDF
- 8. Ohki A, Takeuchi H, Abe N. Endoscopic full-thickness resection for gastric submucosal tumor (with video). Gastroenterol Endosc 2023;65:1246–1254.Article
- 9. Fähndrich M, Sandmann M. Endoscopic full-thickness resection for gastrointestinal lesions using the over-the-scope clip system: a case series. Endoscopy 2015;47:76–79.ArticlePubMed
- 10. Ego M, Abe S, Nonaka S, et al. Endoscopic closure utilizing endoloop and endoclips after gastric endoscopic submucosal dissection for patients on antithrombotic therapy. Dig Dis Sci 2021;66:2336–2344.ArticlePDF
- 11. Fujii T, Ono A, Fu KI. A novel endoscopic suturing technique using a specially designed so-called "8-ring" in combination with resolution clips (with videos). Gastrointest Endosc 2007;66:1215–1220.ArticlePubMed
- 12. Sakamoto N, Beppu K, Matsumoto K, et al. "Loop Clip", a new closure device for large mucosal defects after EMR and ESD. Endoscopy 2008;40 Suppl 2:E97–E98.ArticlePubMed
- 13. Nishiyama N, Kobara H, Kobayashi N, et al. Novel endoscopic ligation with O-ring closure involving muscle layer of a gastric artificial defect. Endoscopy 2020;52:E413–E414.ArticlePubMed
- 14. Inoue H, Tanabe M, Shimamura Y, et al. A novel endoscopic purse-string suture technique, "loop 9", for gastrointestinal defect closure: a pilot study. Endoscopy 2022;54:158–162.ArticlePubMed
- 15. Nomura T, Sugimoto S, Temma T, et al. Clip-line closure with the reopenable clip over line method for a large mucosal defect after gastric endoscopic submucosal dissection. Endoscopy 2022;54:E1–E2.ArticlePubMed
- 16. Inoue H, Yamamoto K, Navarro MJ, et al. Antireflux mucoplasty, an evolution of endoscopic antireflux therapy for refractory GERD. VideoGIE 2023;8:435–440.ArticlePubMedPMC
- 17. Zhang LY, Bejjani M, Ghandour B, et al. Endoscopic through-the-scope suturing. VideoGIE 2022;7:46–51.ArticlePubMedPMC
- 18. Banno S, Nishizawa T, Kinoshita S, et al. Endoscopic mucosa-submucosal clip closure method. Endoscopy 2017;49:E307–E308.ArticlePubMed
- 19. Shi Q, Chen T, Zhong YS, et al. Complete closure of large gastric defects after endoscopic full-thickness resection, using endoloop and metallic clip interrupted suture. Endoscopy 2013;45:329–334.ArticlePubMed
- 20. Inoue H, Shimamura Y, Fukuda M, et al. "Loop-10" line-assisted clip closure method: closure of perforation in re-do peroral endoscopic myotomy. VideoGIE 2023;8:186–188.Article
- 21. Tani Y, Uedo N, Nomura T. Reopenable-clip over-the-line method for closure of gastric endoscopic full-thickness resection defect. Dig Endosc 2023;35:e85–e86.ArticlePubMed
- 22. Canakis A, Dawod SM, Dawod E, et al. Efficacy, feasibility, and safety of the X-Tack endoscopic HeliX tacking system: a multicenter experience. J Clin Gastroenterol 2024;58:1052–1057.ArticlePubMed
- 23. Kantsevoy SV, Bitner M, Mitrakov AA, et al. Endoscopic suturing closure of large mucosal defects after endoscopic submucosal dissection is technically feasible, fast, and eliminates the need for hospitalization (with videos). Gastrointest Endosc 2014;79:503–507.ArticlePubMed
- 24. Goto O, Sasaki M, Akimoto T, et al. Endoscopic hand-suturing for defect closure after gastric endoscopic submucosal dissection: a pilot study in animals and in humans. Endoscopy 2017;49:792–797.ArticlePubMed
- 25. Minato Y, Mori H, Ito F. Endoscopic suturing using a new device to prevent adverse events after endoscopic submucosal dissection: double-arm-bar Suturing System. Dig Endosc 2022;34:e9–e11.ArticlePubMedPDF
- 26. Sharaiha RZ, Kumta NA, DeFilippis EM, et al. A large multicenter experience with endoscopic suturing for management of gastrointestinal defects and stent anchorage in 122 patients: a retrospective review. J Clin Gastroenterol 2016;50:388–392.ArticlePubMed
- 27. Minato Y, Mori H, Ito F. Tips for endoscopic suturing using the double-arm suturing system. Gastroenterol Endosc 2023;65:1144–1154.Article
- 28. Goto O, Koizumi E, Higuchi K, et al. Endoscopic full-thickness resection with double-layer closure by endoscopic hand suturing for a gastric subepithelial tumor. Endoscopy 2022;54:E964–E965.ArticlePubMedPMC
- 29. Schmidt A, Bauder M, Riecken B, et al. Endoscopic full-thickness resection of gastric subepithelial tumors: a single-center series. Endoscopy 2015;47:154–158.ArticlePubMed
- 30. Shang E, Hasenberg T, Magdeburg R, et al. First experiences with A circular stapled gastro-jejunostomy by a new transorally introducible stapler system in laparoscopic Roux-en-Y gastric bypass. Obes Surg 2009;19:230–236.ArticlePubMedPDF
Citations
Citations to this article as recorded by