Skip Navigation
Skip to contents

Clin Endosc : Clinical Endoscopy

OPEN ACCESS

Articles

Page Path
HOME > Clin Endosc > Ahead-of print articles > Article
Editorial From learning curves to competency curves in colorectal endoscopic submucosal dissection
Dong Hoon Baekorcid

DOI: https://doi.org/10.5946/ce.2026.338
Published online: September 9, 2026

Department of Internal Medicine, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, Busan, Korea

Correspondence: Dong Hoon Baek Department of Internal Medicine, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, 179 Gudeok-ro, Seo-gu, Busan 49241, Korea E-mail: dhbeak77@gmail.com
• Received: July 7, 2026   • Revised: July 21, 2026   • Accepted: July 31, 2026

© 2026 Korean Society of Gastrointestinal Endoscopy

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 570 Views
  • 78 Download
See the article "Learning curve of pocket-creation method–assisted colorectal endoscopic submucosal dissection: a single-operator retrospective observational study from South Korea using cumulative sum analysis".
Colorectal endoscopic submucosal dissection (C-ESD) has become the preferred organ-preserving treatment for selected superficial colorectal neoplasms, enabling en bloc and R0 resections regardless of lesion size. Nevertheless, unlike gastric ESD, C-ESD remains technically demanding because of the thin colonic wall, limited scope maneuverability, sharp angulations, and limited submucosal working spaces. As the indications continue to expand worldwide, the central challenge has shifted from determining whether C-ESD can be performed to defining how endoscopists can safely and efficiently acquire competency.
In this issue of Clinical Endoscopy, Kim1 addresses this important question by evaluating the learning process of pocket-creation method (PCM)–assisted C-ESD using cumulative sum (CUSUM) analysis. CUSUM analysis is a sequential statistical method that plots the cumulative difference between observed outcomes and a predefined performance standard, enabling continuous graphical monitoring of whether the performance remains within acceptable limits across successive procedures. PCM is a dissection strategy in which a submucosal pocket is created beneath the lesion before a circumferential mucosal incision is made, thereby preserving the submucosal cushion, stabilizing the endoscope, and providing intrinsic traction. Among 147 consecutive procedures performed by a single operator, procedural efficiency improved steadily, technical performance stabilized after approximately 60 cases, and operator experience, not lesion-related complexity, was the strongest determinant of technical failure. Rather than simply reporting procedural outcomes, the authors provided an objective framework for assessing competency acquisition during C-ESD.
The significance of this study extends beyond identifying a numerical threshold. Traditionally, learning curves in endoscopy have been expressed as the number of procedures required to achieve proficiency.2-4 However, procedural volume alone is an imperfect surrogate for competency. Individual learning rates differ substantially according to prior experience, mentorship, case selection, and the procedural environment. Competency encompasses multiple domains, including technical execution, judgment, complication management, procedural efficiency, and oncological quality. Therefore, quantitative methods such as CUSUM analysis5 represent an important advancement because they evaluate performance continuously, rather than assuming that competency is achieved automatically after a predefined number of cases.
Another notable aspect of this study is its focus on PCM. Since its introduction, the PCM has substantially improved the technical approach to C-ESD.6-8 By creating a confined submucosal pocket before circumferential incision, the technique maintains the submucosal cushion, stabilizes the endoscope, generates intrinsic traction, and maintains a dissection plane parallel to the muscularis propria. These characteristics improve visualization while reducing unnecessary scope movements, thereby facilitating safer and more reproducible dissections. By reducing procedural instability and standardizing tissue exposure, PCM may also reduce interoperator variability during training, thereby supporting the development of standardized competency. Recent guidelines and technical reviews have emphasized that PCM is a cornerstone strategy in contemporary C-ESD, particularly when dedicated traction devices are unavailable, reflecting its growing acceptance in routine clinical practice.9,10
One of the most intriguing findings reported by Kim1 is that lesion-related characteristics, including tumor size, location, histology, and invasion depth, were not independent predictors of technical failure after adjustment, whereas the learning phase remained the dominant determinant. Although these observations should be interpreted cautiously because of the limited number of failure events, they reinforce a clinically important educational message: during the early phase of C-ESD, operator experience exerts a greater influence on technical success than lesion complexity. This finding has direct implications for training programs. Although careful case selection remains important, structured mentorship, standardized techniques, and continuous objective feedback may be even more critical in accelerating safe competency acquisition.11
This study also encourages us to reconsider how competency should be assessed in advanced endoscopy. For decades, procedural numbers have served as convenient benchmarks for credentials. However, performing 60 procedures does not necessarily imply equivalent proficiency across operators or institutions. Future competency assessments will likely incorporate objective quality indicators, including en bloc and R0 resection rates, adverse event profiles, dissection efficiency, and decision-making during challenging situations. Such a transition from volume- to performance-based assessment parallels broader changes in competency-based medical education and may ultimately provide a more reliable framework for both training and credentialing.
Looking forward, the evolution of C-ESD training is likely to extend beyond technical refinement. Artificial intelligence-assisted video review, simulation-based education, digital coaching platforms, and automated performance analysis may soon complement conventional apprenticeship models.12 In this context, the question is no longer simply “How many cases are enough?” but rather “How should competencies be defined, measured, and continuously improved?”
Therefore, the greatest contribution of the present study was not the identification of a stabilization point after approximately 60 PCM-assisted procedures. Instead, it challenges the long-standing assumption that competency can be represented by procedural volume alone. By combining a standardized dissection strategy with objective performance monitoring, Kim1 moves the field beyond describing learning curves to defining competency curves. This conceptual shift may ultimately prove to be more influential than the numerical threshold and provide an important foundation for the next generation of C-ESD education.
  • 1. Kim JH. Learning curve of pocket-creation method-assisted colorectal endoscopic submucosal dissection: a single-operator retrospective observational study from South Korea using cumulative sum analysis. Clin Endosc 2026 [Epub ahead of print].Article
  • 2. Hotta K, Oyama T, Shinohara T, et al. Learning curve for endoscopic submucosal dissection of large colorectal tumors. Dig Endosc 2010;22:302–306.ArticlePubMed
  • 3. Probst A, Golger D, Anthuber M, et al. Endoscopic submucosal dissection in large sessile lesions of the rectosigmoid: learning curve in a European center. Endoscopy 2012;44:660–667.ArticlePubMed
  • 4. Khalaf MA, Ayoub F, Staggers KA, et al. Learning curve for endoscopic submucosal dissection (ESD) in the United States: large, untutored, single-operator experience. Endosc Int Open 2024;12:E905–E913.ArticlePubMedPMC
  • 5. Lim TO, Soraya A, Ding LM, Morad Z. Assessing doctors' competence: application of CUSUM technique in monitoring doctors' performance. Int J Qual Health Care 2002;14:251–258.ArticlePubMed
  • 6. Hayashi Y, Miura Y, Yamamoto H. Pocket-creation method for the safe, reliable, and efficient endoscopic submucosal dissection of colorectal lateral spreading tumors. Dig Endosc 2015;27:534–535.ArticlePubMedPDF
  • 7. Yamashina T, Hayashi Y, Fukuda H, et al. The pocket-creation method may facilitate endoscopic submucosal dissection of large colorectal sessile tumors. Endosc Int Open 2020;8:E1021–E1030.ArticlePubMedPMC
  • 8. Takezawa T, Hayashi Y, Shinozaki S, et al. The pocket-creation method facilitates colonic endoscopic submucosal dissection (with video). Gastrointest Endosc 2019;89:1045–1053.ArticlePubMed
  • 9. Pimentel-Nunes P, Libânio D, Bastiaansen BAJ, et al. Endoscopic submucosal dissection for superficial gastrointestinal lesions: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2022. Endoscopy 2022;54:591–622.ArticlePubMedPMC
  • 10. Akimoto T, Yahagi N, Kato M. Facilitating colorectal endoscopic submucosal dissection: devices and techniques. Tech Innov Gastrointest Endosc 2025;27:250932.Article
  • 11. Calabrese G, Maida M, Elkholy S, et al. Real-world practices and barriers in endoscopic submucosal dissection training: international comprehensive survey. Endosc Int Open 2026;14:a28133195.ArticlePubMedPMC
  • 12. Ho JCL, Qian Z, Lau LHS, et al. Artificial Intelligence in Digestive Endoscopy Training-The Past, Present, and Future. Dig Endosc 2026;38:e70047.ArticlePubMedPMCPDF

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        From learning curves to competency curves in colorectal endoscopic submucosal dissection
        Close
      • XML DownloadXML Download
      Related articles
      From learning curves to competency curves in colorectal endoscopic submucosal dissection
      From learning curves to competency curves in colorectal endoscopic submucosal dissection

      Clin Endosc : Clinical Endoscopy Twitter Facebook
      Close layer
      TOP